Vadodara
+919979119649

'one analog output'

Items tagged with 'one analog output'

product image
Level Transmitter

NRG GLOBAL INSTRUMENTS MAKE microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-15 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action ACTION PARAMETER - if we mention the value of action parameter as 1 then it will work in reverse order and if value is mentioned as 0 it will work in forward order. RANGE PARAMETER – in range parameter we have to define that value which gives the output of 420mA. WORKING OF TRANSMITTER- (REVERSE ACTION ) if we mention the value of action parameter as 1 , suppose the object is placed 1 m (value of range parameter ) from the transmitter then this value will be considered zero and as the object will move closer to it ,it will begin to sense the distance and will give the output as soon as when the object will be at 22cm it will display maximum range i.e 420 mA. Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Transmitter

NRG GLOBAL MAKE microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-15 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action ACTION PARAMETER - if we mention the value of action parameter as 1 then it will work in reverse order and if value is mentioned as 0 it will work in forward order. RANGE PARAMETER – in range parameter we have to define that value which gives the output of 420mA. WORKING OF TRANSMITTER- (REVERSE ACTION ) if we mention the value of action parameter as 1 , suppose the object is placed 1 m (value of range parameter ) from the transmitter then this value will be considered zero and as the object will move closer to it ,it will begin to sense the distance and will give the output as soon as when the object will be at 22cm it will display maximum range i.e 420 mA. Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Transmitter

This is microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-10 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action

Send Message
product image
Tank Level Indicator 3

This is micro-processor based Donnelly Chute level Transmitter with isolated o/p (4-20 mA), 10nos digital optical o/p and 2 relay control .The instrument is field programmable and user friendly. In this Instrument user can set sensor sensitivity, sensor level selection, sample delay time and relay set point etc. The user can set level 2-10 then instrument automatically tunes for o/p 4-20 mA and display 0-100%. The instrument has five settable parameters like rL1,rL2,snt,trl,Lst. The Instrument reads input level in sequence 1 to 10 if misplaced any level then it will not show above levels. Operations Manual – Donnelly Chute Level Transmitter with Modbus Communication Model M11 NX Operations Manual – Donnelly Chute Level Transmitter with Modbus Communication Model M11 MAX Parameters Snt: Sensor Sensitivity adjustment Lst: Level Sensor selection (2-10) Trl: sample Delay adjustment RL1 and rL2 : Relay set point (0-100) snt(sensitivity adjustment Parameter) In this parameter user can set sensitivity of every (1-10 sensor) level sensor through key pad. The sensor value can be set in this parameter 93(Max.) to (185min.) sensitivity and it is normally set 100 value of every sensor. If snt set 93 then i/p led direct on without input connection. Lst(level selection parameter) The user can be set input level 2-10 then instrument automatically tune for o/p 4-20 mA and display 0-100% Trl = 20 set rL1,rL2 : Relay set point value Terminal Details S1 to S10 : i/p for probe type level sensor GND : Common terminal of probe sensor (Donnelly chute sensor) L1 to L10 :o/p for isolated digital out put to plc +24vdc : +v common (+24 vdc) for plc digital i/p O/p 4-20 mA : mA output (isolated) P : common terminal of Relay N/O : Normaly open terminal of Relay N/C : Normaly close terminal of relay L : Phase of 220v AC @50/60Hz N : Neutral E : Earth Specifications Main (auxiliary supply) : 220vAc +-15% @50 Hz O/P (Analog) : isolated 4-20mA O/p (digital : isolated digital output (L1 to L10) Relay set value : 000-100 settable Display range : 0-100% according select sensor level (2-10) settable Time delay setting : 001-100 ms settable Input :10nos. Probe sensor (digital i/p) Digital i/p / o/p : Indicate by LED as fitted on the front panel LED : Red Led for i/p, Green Led optical digital o/p Control Relay : one pair normally open potential free contact: @ 5A at 240v AC Overall size : 96x194x223 mm (WxHxD ) Panel cutout : 184X92mm(HxW) Configuration 1st press both PRG+ DN key for 5 seconds then display rL1 press ENT key display last load value if change then Use up/dn key and press ENT key display rL2 press ENT key display last load value if change then use up/dn key And press ENT key display snt press ENT display 001(it means level 1 select to adjust sensitivity) press ENT display last load value of sensor 1 sensitivity , if you want change value then use up/dn if value decrees (it means sensitivity higher side(93 max.) ) if value increase (it means sensitivity lower side(185 min.) if you want to store modified value then press and hold PRG key after press ENT key now release both key now modified value has been stored . If you do not want to change in this parameter then use only ENT key, if press only ENT key it means by pass snt parameter, if press PRG key and ENT key it means modified value stored and display snt for next level sensor sensitivity calibration And same process apply for level 1 to level 10 after that, Next parameter Lst display press ENT key display last level select if change (2-10) then use up/dn key press ENT key display trL press ENT key display last value and set 20 and press ENT key and now exit configuration mode.

Send Message
product image
Level Switch

NRG GLOBAL INSTRUMENTS MAKE magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC OR 230 VAC 1 AMP Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters.. other on your request Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Switch

1. Product Description NRG GLOBAL Introduced magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters 3. Design features 1. One Moving Component Exists, so that no – wear of float. 2. Suitable for any fluid having Specific Gravity Above 0.7 3. Minimum possible Distance between 2 Level set Points is 75 mm. 4. Accuracy : ± 0.10%, ± 0.25 %, ± 0.5 % on F.S. 5. The switch operates on the principle of magnetic flux coupling with no mechanical connection so that fluid contamination of switch components cannot occur. 4. Ordering Information Information Required to Quote: Material of Construction, Service Medium, Specific Gravity, Max. Pressure & Temperature, Number of Actuating Levels & Their Distance from top of the Connection, Process Connection.

Send Message
product image
Level Switch

1. Product Description NRG GLOBAL Introduced magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters 3. Design features 1. One Moving Component Exists, so that no – wear of float. 2. Suitable for any fluid having Specific Gravity Above 0.7 3. Minimum possible Distance between 2 Level set Points is 75 mm. 4. Accuracy : ± 0.10%, ± 0.25 %, ± 0.5 % on F.S. 5. The switch operates on the principle of magnetic flux coupling with no mechanical connection so that fluid contamination of switch components cannot occur. 4. Ordering Information Information Required to Quote: Material of Construction, Service Medium, Specific Gravity, Max. Pressure & Temperature, Number of Actuating Levels & Their Distance from top of the Connection, Process Connection. Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Pressure Gauge

Pressure gauges are instruments designed to measure the pressure of media in a system. Measuring the pressure in your system is a critical quality step to ensure consistency of a product and safety check to be aware of leaks or building pressure in a system. Before specifying a gauge, it is important to understand the basic principles of what pressure is. Then the correct pressure gauge can be determined based on selection criteria, to accurately measure the pressure within the system. Even the best measuring equipment produces a certain deviation from the actual value. It is important to know how this measurement accuracy is defined. Digital gauges in comparison with analog ones have higher accuracy. Read our article on digital pressure gauges if you want to learn more about that type. Additional Information: Item Code: pg Production Capacity: Weeek Delivery Time: week Packaging Details: Export Worthy packing

Send Message
product image
Level Transmitter

NRG MAKE Float level transmitter provides continuous level measurement up to 2 m (6.5') with a 4 to 20 mA signal output, and is factory configured to your selected dimension. This stainless steel liquid level sensor is well suited for high temperature or pressure tank level applications with relatively clean liquids such as water, diluted chemicals and light weight oils. Typical application examples include boilers and process vessels. Specifications Range: 41 to 1222 cm (16 to 48") Accuracy: 0.25% span in water Configuration: None, fixed span Orientation: ±20° from vertical Specific Gravity: 0.55 min Supply Voltage: 10 to 30 Vdc Loop Resistance: 600 Ω @ 24 Vdc Signal Output: 4 to 20 mA, two-wire Process Temp: -40 to 85°C (-40 to 185°F) Ambient Temp: -40 to 60°C (-40 to 140°F) Pressure: 200 psi (13.8 bar) Enclosure Rating: NEMA 4X (IP65) Enclosure Material: PP Conduit Entrance: Single, 1/2 NPT Process Mount: 2 NPT Guide-Float Material: 316 SS Classification: General purpose Additional Information: Item Code: flt Production Capacity: 50 Delivery Time: week Packaging Details: Export worthy packing

Send Message

Still searching for
one analog output?