Vadodara
+919979119649

'water supply networks'

Items tagged with 'water supply networks'

product image
Flow Meter

Description : FEDREL / KRANTI Make Woltman Type Water Meter (Cold) Size range : 40 To 500 MM(1½” To 20”) Temp Range : 0°C to 45°C Accuracy Class :Class B (±2 % @ Nominal flow rate) Product Standard : ISO-4064/IS-2373 Body Material cum Standard : IS-210 Gr. FG-200 Dial Details : Magnetic Drive, Extra Dry Dial Protection Class : IP-68 End Details : Flanged Ends to BS: 4504 PN 16 APPLICATIONS · Water Supply Networks · Industries · Agriculture FEATURES AND BENEFITS · Extra Dry Dial · Hermetically sealed register ensures that all internal parts clean and prevents fogging throughout the entire lifetime of the meter. · Robust type body to pass the strongest resistance tests in both static and dynamic conditions. · High quality engineered materials for hydraulics and register pivot ensure high reliability and durability · Shock –resistant material for register and closure. · High performance magnetic transmission ensures no part of the register is in contact with water · Interchangeable spare parts for easy online maintenance · High sensitivity, low pressure loss · In-line strainers are standard. · Available for both cold and hot water. 100% of the products are calibrated and all calibrations results can be provided · Temperature Range = 45°c Description : FEDREL / KRANTI Make Woltman Type Water Meter (Cold) Size range : 40 To 500 MM(1½” To 20”) Temp Range : 0°C to 45°C Accuracy Class :Class B (±2 % @ Nominal flow rate) Product Standard : ISO-4064/IS-2373 Body Material cum Standard : IS-210 Gr. FG-200 Dial Details : Magnetic Drive, Extra Dry Dial Protection Class : IP-68 End Details : Flanged Ends to BS: 4504 PN 16 Additional Information: Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PAKING

Send Message
product image
Flow Meter

NRG GLOBAL OFFER WATERMETERDOMESTIC WATER METER SPECIFICATIONS (15MM, 20MM AND 25MM SIZES) 1.1 GENERAL LAYOUT The complete water meter is to consist of (5) components:  Above ground extruded water meter box and extended lid with slider.  A water meter (Plastic bodied 15mm, 20mm and 25mm) class C volumetric rotary piston liquid sealed register) with unique meter serial number where first two digits indicate year of manufacture.  3 way concentric restrictor valve.  SABS (Blue) lever type consumer ball valve.  Fusion welded PPR pipe assembly tested to 25 bar Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: CORUGATED BOX

Send Message
product image
Flow Meter

· Full Bore Electromagnetic Flow Meter · Best Accuracy :- +/- 0.5 % Of Reading · Excellent Measuring Accuracy To Low Velocity, Measure Double Directions Flows · Buried Sensor (IP 68) No need Measure Well While Instillation; · Precision Coil Winding Technology, Make Magnetic Field More Uniform · Build-in Reference Electrode, No Need Connect Ground Ring; · Dual Frequency Excitation And Stubble Zero Point; · Self-Diagnostic Function, And Intelligent Operation APPLICATION: · ETP/STP Plant · Bore Well Water · Water Base Chemical Mixing Plant · Water Bathing Plant · Ro Plant · Starch Slurry · Food Mixing Plant · Pumping Station Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Flow Meter

NRG GLOBAL INSTRUMENTS MAKE Electromagnetic Flow Meters, simply known as mag flow meter is a volumetric flow meter which is ideally used for waste water applications and other applications that experience low pressure drop and with appropriate liquid conductivity required.The device doesn’t have any moving parts and cannot work with hydrocarbons and distilled water. Mag flow meters are also easy to maintain.Electromagnetic Flow Meters Principle of Magnetic Flow Meter Based on Faraday’s LawMagnetic flow meters works based on Faraday’s Law of Electromagnetic Induction. According to this principle, when a conductive medium passes through a magnetic field B, a voltage E is generated which is proportional to the velocity v of the medium, the density of the magnetic field and the length of the conductor. [E is the voltage generated in a conductor, V is the velocity of the conductor, B is the magnetic field strength and L is the length of the conductor].It is very important that the liquid flow that is to be measured using the magnetic flow meter must be electrically conductive. The Faraday’s Law indicates that the signal voltage (E) is dependent on the average liquid velocity (V), the length of the conductor (D) and the magnetic field strength (B). The magnetic field will thus be established in the cross-section of the tubeBasically when the conductive liquid flows through the magnetic field, voltage is induced. To measure this generated voltage (which is proportional to the velocity of the flowing liquid), two stainless steel electrodes are used which are mounted opposite each other.The two electrodes which are placed inside the flow meter are then connected to an advanced electronic circuit that has the ability to process the signal. The processed signal is fed into the microprocessor that calculates the volumetric flow of the liquid.Electromagnetic Flow Meters Formula:Electromagnetic flow meters use Faraday’s law of electromagnetic induction for making a flow measurement. Faraday’s law states that, whenever a conductor of length ‘l’ moves with a velocity ‘v’ perpendicular to a magnetic field ‘B’, an emf ‘e’ is induced in a mutually perpendicular direction which is given byThus the volume flow rate is proportional to the induced emf. In Practical applications we have to enter the meter constant ‘K’ value in magnetic flow meter which is available in vendor catalog/manual.Applications of Magnetic Flow MetersThis electromagnetic flow meter being non intrusive type, can be used in general for any fluid which is having a reasonable electrical conductivity above 10 microsiemens/cm.Fluids like sand water slurry, coal powder, slurry, sewage, wood pulp, chemicals, water other than distilled water in large pipe lines, hot fluids, high viscous fluids specially in food processing industries, cryogenic fluids can be metered by the electromagnetic flow meter Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Transmitter

NRG MAKE Float level transmitter provides continuous level measurement up to 2 m (6.5') with a 4 to 20 mA signal output, and is factory configured to your selected dimension. This stainless steel liquid level sensor is well suited for high temperature or pressure tank level applications with relatively clean liquids such as water, diluted chemicals and light weight oils. Typical application examples include boilers and process vessels. Specifications Range: 41 to 1222 cm (16 to 48") Accuracy: 0.25% span in water Configuration: None, fixed span Orientation: ±20° from vertical Specific Gravity: 0.55 min Supply Voltage: 10 to 30 Vdc Loop Resistance: 600 Ω @ 24 Vdc Signal Output: 4 to 20 mA, two-wire Process Temp: -40 to 85°C (-40 to 185°F) Ambient Temp: -40 to 60°C (-40 to 140°F) Pressure: 200 psi (13.8 bar) Enclosure Rating: NEMA 4X (IP65) Enclosure Material: PP Conduit Entrance: Single, 1/2 NPT Process Mount: 2 NPT Guide-Float Material: 316 SS Classification: General purpose Additional Information: Item Code: flt Production Capacity: 50 Delivery Time: week Packaging Details: Export worthy packing

Send Message
product image
Level Transmitter

NRG GLOBAL INSTRUMENTS MAKE microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-15 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action ACTION PARAMETER - if we mention the value of action parameter as 1 then it will work in reverse order and if value is mentioned as 0 it will work in forward order. RANGE PARAMETER – in range parameter we have to define that value which gives the output of 420mA. WORKING OF TRANSMITTER- (REVERSE ACTION ) if we mention the value of action parameter as 1 , suppose the object is placed 1 m (value of range parameter ) from the transmitter then this value will be considered zero and as the object will move closer to it ,it will begin to sense the distance and will give the output as soon as when the object will be at 22cm it will display maximum range i.e 420 mA. Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Transmitter

NRG GLOBAL MAKE microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-15 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action ACTION PARAMETER - if we mention the value of action parameter as 1 then it will work in reverse order and if value is mentioned as 0 it will work in forward order. RANGE PARAMETER – in range parameter we have to define that value which gives the output of 420mA. WORKING OF TRANSMITTER- (REVERSE ACTION ) if we mention the value of action parameter as 1 , suppose the object is placed 1 m (value of range parameter ) from the transmitter then this value will be considered zero and as the object will move closer to it ,it will begin to sense the distance and will give the output as soon as when the object will be at 22cm it will display maximum range i.e 420 mA. Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Transmitter

This is microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-10 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action

Send Message

Still searching for