Vadodara
+919979119649

'250 c pressure rating'

Items tagged with '250 c pressure rating'

product image
Pressure Transmitter

sanitary pressure transmitters have a flush diaphragm which is suitable for the measurement of viscous fluids or media containing particulates that may clog the pressure connection of standard transmitters. The transmitters have piezoresistive technology which incorporates a silicon sensor. The diaphragm and wetted parts are 316L stainless steel. The stability of the silicon element allows the transmitter to be operated at a higher temperature range; at the same time this makes the zero and sensitivity thermal shifts over the whole operating temperature range of the transmitter very small. • 0...100 bar measuring ranges • 4~20mA current loop output • G1/2 - 1/2" BSP(M) process connection • Flush membrane structure without input pressure hole & cavity • Welded isolated diaphragm • High accuracy, high strength, sanitary type • Dimensions can be customized. • Gauge, absolute and sealed gauge pressure types Additional Information: Production Capacity: 100 Delivery Time: 10 days Packaging Details: export worthy packing

Send Message
product image
Industrial Rotameter

Metal Variable Area Type Flow Meter are designed to measure flow rate of liquids and gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and float. A magnet encapsulated in float couples with rotating magnets are connected to an indicating pointer. Henceforth, the movement of the float is accurately indicated in terms of flowrate. They are intended for application where high pressure, temperature or corrosive conditions preclude the use of conventional glass tube. These are all Metal Variable Area Type Flow meter design to measure flow rate of Liquids & Gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and a float. A magnet encapsulates in float couples with rotating magnets connected to an indicating pointer, thus the movement of the float, is accurately indicated in terms of flow rate. 2. Working Principle When fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 is created between upper and lower side of the float. The float moves upwards by a force obtained by multiplying the pressure differential by the maximum cross-sectional area of the float. Based on Bemoulli's theorem, the principle mentioned above can be theoretically expressed as follows. Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of which the differential pressure decreases. Upward movement of float stops when the dead load is dynamically balanced by the differential pressure. Tapering of metering tube is so designed that the vertical movement of the float becomes linearly proportional to the rate of flow and the scale is provided to read the position of the float, thus giving birth to flow rate indication. 3. Specifications Accuracy : ± 2% of FSD Rangeability : 10:1 Repeatability : ± 0.5% Temperature Rating : -200 to 250°C Pressure Rating : 40 Bar Flow Direction : Bottom to Top Connections : Flanged, TC End and Screwed Enclosure : IP 65 Weatherproof 4. Design features 1. Simplified piping and reduced space requirements 2. Permanent magnetic link between metering float and motion position transmitter 3. Precision swaged metering tube 4. Guide cartridges easily removable for cleaning 5. Provide with Electrical transmitter, flow indicator or alarm 6. Available F/F Height in 350, 450, 500 mm 7. Available Flange size 15 NB to 150 NB & Flow 200 LPH to 50,000 LPH

Send Message
product image
Level Switch

NRG GLOBAL INSTRUMENTS MAKE magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC OR 230 VAC 1 AMP Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters.. other on your request Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Switch

NRG GLOBAL MAKE Displacer type level switches offers the industrial user a wide choice of alarm and control configuration. DLS works on a simple buoyancy principle and is well suited for simple or complex applications, such as forming surging liquids or agitated fluids, and usually costs less than other types of level switches. CONSTRUCTION & OPERATION Operation is based on simple buoyancy principle. As the liquid level rises and progressively immerses the displacer elements, the effective weight suspended on the spring reduces and the consequent length of the spring change is used to provide magnet movement and operate the switch. The spring movement causes the magnetic sleeve to attract a pivoted magnet actuating a switch mechanism located outside the barrier tube. Built-in limit stops, prevent over stroking under level surge conditions. FEATURES: • Wide choice of switching functions • Suitable for large tanks up to 15 meters • Site adjustable switch points • Customized for high temp, high pressure & vaccum applications. • Reliable performance in turbulent liquids even without still pipes. • Easy transportation of longer length switches. • Enclosure : Weather proof-IP-65 Ex-proof-Gr. IIA & IIB or IIC GENERAL SPECIFICATIONS: Enclosure : Cast ALUMINIUM, Weather Proof-IP 65, Cast AL Ex-proof Gr. IIA & IIB or IIC Conduit Connection : ¾ ” ET or ½” NPT Measuring Range : 200 mm~15000 mm Operating Differential : 40±5 mm / Adjustable / 65 ±5 mm Switch Type : Micro switch Switch Contacts : 2 SPDT (2 NO + 2 NC) @ 5A, 230 VAC (Resistive) Switch Action : Bistable Terminals : To suit 1.5 mm2 conductor Flexible Rope : SS304, SS316, PP, PTFE Displacer : SS304, SS316, PP, PTFE Spring Housing : SS316, PP, PTFE Spring Material : SS316, SS316L Process Connection Flanged : MS, SS304, SS316, PP (SS clad), PTFE (SS clad) Perforated still well : MS, SS304, SS316, PP (65 NB) External Cage : MS, SS304, SS316, PP (80 NB) Max. Temperature : 0-200°C (without cooling fins) 0-300°C (with cooling fins) (Contact factory for temperature more than 300°C) Max. Test Pressure : Vaccum to 40 Kg/cm2 (Contact factory for pressure more than 40 Kg/cm2) Min. Sp. Gravity : 0.7 (Contact factory for Sp. Gr. less than 0.7)

Send Message
product image
Level Switch

NRG GLOBAL MAKE side-mounted float level switch is suitable for liquid level control of open or bearing pressure container in industrial process. When the liquid level reaches to high or low limit, relay contact point can be as signal alarm device or the switch in electronic pump circuit. It is used in water treatment, petrochemical, furnace, shipyard etc. It is widely applicable in the condition of high viscosity, high pressure, high temperature because of it is flexible structure, and it can replace the UQK series products. Working principle To use of liquid buoyancy principle. When the floating ball due to buoyancy and moving up and down, the magnetic reed switch in the junction box will be action when it is influence by the arm end magnetic. The same principle is used in the micro switch device. To use of magnets and magnet micro switch arm end of mutual exclusion movement to push the micro switch action. Product purpose SM series float level switch is suitable for liquid level control of open or bearing pressure container in industrial process. When the liquid level reaches to high or low limit, relay contact point can be as signal alarm device or the switch in electronic pump circuit. Specification Application : Liquids Liquid Density : Above 0.5 – 2.0 Liquid Velocity : Upto 500 cp Design Pressure : Upto 40 Kg/cm² Design Temp : Upto 300°C Connection : Flanged to ASA/BS/DIN Screwed BSP/Screwed NPT Material : SS304/SS304L/SS316/SS316L/PP/HDPE/PVC/PVDF Lined/PTFE Lined Other Materials on request Switch Type : Micro, SDPT, DPDT Form : 1 NO+1NC / 2NO+2NC Rating : 5 Amp, 230 VAC OR 24 VDC Enclosure : W-Proof IP65 / Ex-Proof Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Switch

1. Product Description NRG GLOBAL Introduced magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters 3. Design features 1. One Moving Component Exists, so that no – wear of float. 2. Suitable for any fluid having Specific Gravity Above 0.7 3. Minimum possible Distance between 2 Level set Points is 75 mm. 4. Accuracy : ± 0.10%, ± 0.25 %, ± 0.5 % on F.S. 5. The switch operates on the principle of magnetic flux coupling with no mechanical connection so that fluid contamination of switch components cannot occur. 4. Ordering Information Information Required to Quote: Material of Construction, Service Medium, Specific Gravity, Max. Pressure & Temperature, Number of Actuating Levels & Their Distance from top of the Connection, Process Connection.

Send Message
product image
Level Switch

1. Product Description NRG GLOBAL Introduced magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters 3. Design features 1. One Moving Component Exists, so that no – wear of float. 2. Suitable for any fluid having Specific Gravity Above 0.7 3. Minimum possible Distance between 2 Level set Points is 75 mm. 4. Accuracy : ± 0.10%, ± 0.25 %, ± 0.5 % on F.S. 5. The switch operates on the principle of magnetic flux coupling with no mechanical connection so that fluid contamination of switch components cannot occur. 4. Ordering Information Information Required to Quote: Material of Construction, Service Medium, Specific Gravity, Max. Pressure & Temperature, Number of Actuating Levels & Their Distance from top of the Connection, Process Connection. Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message

Still searching for
250 c pressure rating?