Level Transmitter

NRG GLOBAL INSTRUMENTS MAKE microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-15 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action ACTION PARAMETER - if we mention the value of action parameter as 1 then it will work in reverse order and if value is mentioned as 0 it will work in forward order. RANGE PARAMETER – in range parameter we have to define that value which gives the output of 420mA. WORKING OF TRANSMITTER- (REVERSE ACTION ) if we mention the value of action parameter as 1 , suppose the object is placed 1 m (value of range parameter ) from the transmitter then this value will be considered zero and as the object will move closer to it ,it will begin to sense the distance and will give the output as soon as when the object will be at 22cm it will display maximum range i.e 420 mA. Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Transmitter

NRG GLOBAL MAKE microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-15 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action ACTION PARAMETER - if we mention the value of action parameter as 1 then it will work in reverse order and if value is mentioned as 0 it will work in forward order. RANGE PARAMETER – in range parameter we have to define that value which gives the output of 420mA. WORKING OF TRANSMITTER- (REVERSE ACTION ) if we mention the value of action parameter as 1 , suppose the object is placed 1 m (value of range parameter ) from the transmitter then this value will be considered zero and as the object will move closer to it ,it will begin to sense the distance and will give the output as soon as when the object will be at 22cm it will display maximum range i.e 420 mA. Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Transmitter

This is microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-10 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action

Send Message
product image
Level Indicator

Reflex level guage applicable upto 200 kg/cm and upto 400 deg cent Cryo applications upto -196 deg cent Toughened borosilicate glass with serrations For applicability in critical, acidic, cryo and temperature zone IBR certified device available NACE, H2S service compatibility applicable Non frost extension Heat tracing available Applicable for refinery, petrochemical, chemical, power, radioactive, fertilizer, food, pharma, metal industry applications Additional Information: Production Capacity: 100 Delivery Time: 3 -4 WEEK Packaging Details: EXPORTWORTHY

Send Message
product image
Level Transmitter

The 80GHz Radar series is NRG radar operating at 76-81 GHz, which has a maximum measuringrange of 120m and nearly zero blind zone. It supports 4-wire and 2-wire applications.Higher operating frequency and shorter wavelength make it ideal for solid applications, includingthose with extreme dust and high temperature to + 2000. Built-in rich algorithm ensure stable outputeven in the application with fast agitator.The main benefitsBased on the self-developed CMOS millimeter wave RF chip, a more compact RF architecture,a higher signal-to-noise ratio, and nearly zero blind zone are realized.5GHz working bandwidth means higher measurement resolution and accuracy.3°antenna beam angle, so the interference in the environment has less impact on the instrument,and the installation is more convenient.Shorter wavelength yields good reflection properties on sloped solids, so aiming towardsmaterial angle of repose is usually not necessary.Remote debugging and remote upgrading is supported to reduce the cost of field personnel

Send Message
product image
Pressure Transmitter

Extended Diaphragm Seal is ideal for highly viscous and dry powder applications. Its unique design eliminates dead space in piping. It is often used for flush mounting in thick-walled vessels and is available in standard and custom lengths.Construction Materials 316L or Hast C-276 Process Temperature Limits -110°F to 750°F Ambient Temperature Limits Determined by the Pressure Instrument Additional Information: Production Capacity: 100 Delivery Time: within a week Packaging Details: Export worthy packing

Send Message
product image
Acrylic Rotameter

NRG GLOBAL INSTRUMENTS MAKE Glass Tube Variable Area Flow Meters (Rotameters) are intended for general in line and ByPass metering applications (i.e. for Gas & Liquid) where operating conditions are with the limitations of Glass metering tubes. These are the principle of Variable Area. The float moves freely up and down tapered borosilicate glass with fluid flow from bottom to top. The float takes up a position where buoyancy forces and the float weight are balanced in proportion to flow rate. The Vertical position of the float as indicated by scale is the measure of the instantaneous flow rate. 2. Principal of Operation When fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 is created between upper and lower side of the float. The float moves upwards by a force obtained by multiplying the pressure differential by the maximum cross-sectional area of the float. Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of which the differential pressure decreases. Upward movement of float stops when the dead load is dynamically balanced by the differential pressure.

Send Message
product image
Flow Instruments

NRG GLOBAL MAKE Metal Variable Area Type Flow Meter are designed to measure flow rate of liquids and gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and float. A magnet encapsulated in float couples with rotating magnets are connected to an indicating pointer. Henceforth, the movement of the float is accurately indicated in terms of flowrate. They are intended for application where high pressure, temperature or corrosive conditions preclude the use of conventional glass tube. These are all Metal Variable Area Type Flow meter design to measure flow rate of Liquids & Gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and a float. A magnet encapsulates in float couples with rotating magnets connected to an indicating pointer, thus the movement of the float, is accurately indicated in terms of flow rate. 2. Working Principle When fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 is created between upper and lower side of the float. The float moves upwards by a force obtained by multiplying the pressure differential by the maximum cross-sectional area of the float. Based on Bemoulli's theorem, the principle mentioned above can be theoretically expressed as follows. Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of which the differential pressure decreases. Upward movement of float stops when the dead load is dynamically balanced by the differential pressure. Tapering of metering tube is so designed that the vertical movement of the float becomes linearly proportional to the rate of flow and the scale is provided to read the position of the float, thusgiving birth to flow rate indication.

Send Message
product image
Flow Rotameter

Metal Variable Area Type Flow Meter are designed to measure flow rate of liquids and gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and float. A magnet encapsulated in float couples with rotating magnets are connected to an indicating pointer. Henceforth, the movement of the float is accurately indicated in terms of flowrate. They are intended for application where high pressure, temperature or corrosive conditions preclude the use of conventional glass tube. These are all Metal Variable Area Type Flow meter design to measure flow rate of Liquids & Gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and a float. A magnet encapsulates in float couples with rotating magnets connected to an indicating pointer, thus the movement of the float, is accurately indicated in terms of flow rate. 2. Working Principle When fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 is created between upper and lower side of the float. The float moves upwards by a force obtained by multiplying the pressure differential by the maximum cross-sectional area of the float. Based on Bemoulli's theorem, the principle mentioned above can be theoretically expressed as follows. Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of which the differential pressure decreases. Upward movement of float stops when the dead load is dynamically balanced by the differential pressure. Tapering of metering tube is so designed that the vertical movement of the float becomes linearly proportional to the rate of flow and the scale is provided to read the position of the float, thus giving birth to flow rate indication. 3. Specifications Accuracy : ± 2% of FSD Rangeability : 10:1 Repeatability : ± 0.5% Temperature Rating : -200 to 250°C Pressure Rating : 40 Bar Flow Direction : Bottom to Top Connections : Flanged, TC End and Screwed Enclosure : IP 65 Weatherproof 4. Design features 1. Simplified piping and reduced space requirements 2. Permanent magnetic link between metering float and motion position transmitter 3. Precision swaged metering tube 4. Guide cartridges easily removable for cleaning 5. Provide with Electrical transmitter, flow indicator or alarm 6. Available F/F Height in 350, 450, 500 mm 7. Available Flange size 15 NB to 150 NB & Flow 200 LPH to 50,000 LPH