Vadodara
+919979119649

'auxiliary supply'

Items tagged with 'auxiliary supply'

product image
Level Transmitter

NRG GLOBAL INSTRUMENTS MAKE microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-15 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action ACTION PARAMETER - if we mention the value of action parameter as 1 then it will work in reverse order and if value is mentioned as 0 it will work in forward order. RANGE PARAMETER – in range parameter we have to define that value which gives the output of 420mA. WORKING OF TRANSMITTER- (REVERSE ACTION ) if we mention the value of action parameter as 1 , suppose the object is placed 1 m (value of range parameter ) from the transmitter then this value will be considered zero and as the object will move closer to it ,it will begin to sense the distance and will give the output as soon as when the object will be at 22cm it will display maximum range i.e 420 mA. Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Transmitter

NRG GLOBAL MAKE microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-15 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action ACTION PARAMETER - if we mention the value of action parameter as 1 then it will work in reverse order and if value is mentioned as 0 it will work in forward order. RANGE PARAMETER – in range parameter we have to define that value which gives the output of 420mA. WORKING OF TRANSMITTER- (REVERSE ACTION ) if we mention the value of action parameter as 1 , suppose the object is placed 1 m (value of range parameter ) from the transmitter then this value will be considered zero and as the object will move closer to it ,it will begin to sense the distance and will give the output as soon as when the object will be at 22cm it will display maximum range i.e 420 mA. Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Transmitter

This is microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-10 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action

Send Message
product image
Tank Level Indicator 3

This is micro-processor based Donnelly Chute level Transmitter with isolated o/p (4-20 mA), 10nos digital optical o/p and 2 relay control .The instrument is field programmable and user friendly. In this Instrument user can set sensor sensitivity, sensor level selection, sample delay time and relay set point etc. The user can set level 2-10 then instrument automatically tunes for o/p 4-20 mA and display 0-100%. The instrument has five settable parameters like rL1,rL2,snt,trl,Lst. The Instrument reads input level in sequence 1 to 10 if misplaced any level then it will not show above levels. Operations Manual – Donnelly Chute Level Transmitter with Modbus Communication Model M11 NX Operations Manual – Donnelly Chute Level Transmitter with Modbus Communication Model M11 MAX Parameters Snt: Sensor Sensitivity adjustment Lst: Level Sensor selection (2-10) Trl: sample Delay adjustment RL1 and rL2 : Relay set point (0-100) snt(sensitivity adjustment Parameter) In this parameter user can set sensitivity of every (1-10 sensor) level sensor through key pad. The sensor value can be set in this parameter 93(Max.) to (185min.) sensitivity and it is normally set 100 value of every sensor. If snt set 93 then i/p led direct on without input connection. Lst(level selection parameter) The user can be set input level 2-10 then instrument automatically tune for o/p 4-20 mA and display 0-100% Trl = 20 set rL1,rL2 : Relay set point value Terminal Details S1 to S10 : i/p for probe type level sensor GND : Common terminal of probe sensor (Donnelly chute sensor) L1 to L10 :o/p for isolated digital out put to plc +24vdc : +v common (+24 vdc) for plc digital i/p O/p 4-20 mA : mA output (isolated) P : common terminal of Relay N/O : Normaly open terminal of Relay N/C : Normaly close terminal of relay L : Phase of 220v AC @50/60Hz N : Neutral E : Earth Specifications Main (auxiliary supply) : 220vAc +-15% @50 Hz O/P (Analog) : isolated 4-20mA O/p (digital : isolated digital output (L1 to L10) Relay set value : 000-100 settable Display range : 0-100% according select sensor level (2-10) settable Time delay setting : 001-100 ms settable Input :10nos. Probe sensor (digital i/p) Digital i/p / o/p : Indicate by LED as fitted on the front panel LED : Red Led for i/p, Green Led optical digital o/p Control Relay : one pair normally open potential free contact: @ 5A at 240v AC Overall size : 96x194x223 mm (WxHxD ) Panel cutout : 184X92mm(HxW) Configuration 1st press both PRG+ DN key for 5 seconds then display rL1 press ENT key display last load value if change then Use up/dn key and press ENT key display rL2 press ENT key display last load value if change then use up/dn key And press ENT key display snt press ENT display 001(it means level 1 select to adjust sensitivity) press ENT display last load value of sensor 1 sensitivity , if you want change value then use up/dn if value decrees (it means sensitivity higher side(93 max.) ) if value increase (it means sensitivity lower side(185 min.) if you want to store modified value then press and hold PRG key after press ENT key now release both key now modified value has been stored . If you do not want to change in this parameter then use only ENT key, if press only ENT key it means by pass snt parameter, if press PRG key and ENT key it means modified value stored and display snt for next level sensor sensitivity calibration And same process apply for level 1 to level 10 after that, Next parameter Lst display press ENT key display last level select if change (2-10) then use up/dn key press ENT key display trL press ENT key display last value and set 20 and press ENT key and now exit configuration mode.

Send Message
product image
Level Switch

Conductivity Level Switch is a simple, low cost, point level measurement switch designed for level detection of conductive liquids having low densities, high viscosities, containing solid particles and to detect interface between non-conductive and conductive liquids. The probes work through the variation of the electrical resistance between the reference electrode and the level-control electrode. Conductivity level switches detect the level resistance when their electrodes are covered by the medium. If the tank is made of plastic, concrete, or any other nonconductive material, an additional electrode is required as a reference Conductivity Level Switches are available with stainless steel 316 electrodes as standard Suitable for many chemicals and aggressive media which are conductive in nature and dirty liquids, liquids with high solid content Construction available with both Solid probes & Suspended probes to suit fitting requirement It is a simple, low cost, point level controller designed for detecton of conductive liquids, having low densites, high viscosities, containing solid particles and interface between nonconductive and conductive liquids. CONSTRUCTION & OPERATION It comprises of a probe, wired to a level controller. The probe holds one common reference/common electrode and one or multiple “Control Electrodes” depending upon the number of levels to be controlled. All the electrodes are suitably insulated to avoid electrical bridging. The lengths of “Control Electrodes” correspond to the height of preset level points to be controlled and the length of the “reference/common Electrode” is kept slightly longer than the longest “Control Electrode”. If tank is conductive, it can be used as a reference/common electrode. Then number of control electrodes equals number of preset levels. Level controller houses sensing electronics consisting of power supply and signal conditoning circuit which provide a “Low AC Voltage” across mass and control electrodes. On liquid reaching preset level point electrical circuit gets completed - generating a signal which is amplified to actuate a relay, those potential free contacts are available for subsequent operations. On “Level Falling” the circuit breaks, deactivating the relay Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PAKING

Send Message
product image
Level Switch

NRG MAKE vibrating fork is a level switch for liquids and is used in tanks, containers and pipelines.As a sturdy replacement of conventional float switch, Elixir offers a variety of built-in featuresnon-existant in floats and other switches, e.g. where materials are sticky, corrosive, agitated,splashing, foaming and having uncertain electrical properties.Elixir vibrating fork is suitablefor hazardous areas, available with explosion-proof housings certified by CMRI , Dhanbad.Features• Less Power Consumption: Less Heat, Long Life• Universal Power Supply: 18 to 55 V DC,90 to 265 V AC on same terminals• Application Temperature Range : up to 200° C• Suitable up to 10,000 cP (Detects all Industrial Fluids)• Compact Size: Less Inventory• Extendable probe length from 68 to 3000 mm• ECTFE coated, polished & hygienic fork• Output: 8.2V Namur, SPDT & DPDT Relay type currentoutput• Calibration Free, independent of material's dielectricpropertiesPrincipleA specially shaped tuning fork is kept vibrating using piezo-electric elements. Typically, thefork vibrates at its natural frequency. The frequency of oscillation for the tuning fork changeswhen immersed in liquids. The change in frequency is detected by the microprocessorleading to a switching decision.Manufacturing Level Instruments & Speed Monitoring SystemsVersion 2.1Grown...to meet challengesELIXIR Microcontrollerbased Vibrating Fork Liquid Level Limit SwitchApprovals CE Marking, RoHS Compliance, IP-67 Marking Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Switch

Nrg global Instruments make conductivity level sensor PRODUCT DETAILS Medium Temp : -20Deg C to 100 Dec C Special Version : Up to 200 Deg C Electronics : -25oC to +65oC Output : 1 sets of potential free c/o contacts rated at 5 amps, 230VAC for resistive loads per switch point Supply Voltage : 12-30 V Dc Mounting Connection : 1/2" Standard for Rod probe, others as per request and application MODELS : 1)Single Point 2) Multipoint up to 4 points NRG GLOBAL INSTRUMENTS is the leading Capacitance Level Switches manufacturer in India which provides the quality products to its customers. The best thing about our manufacturing is that it is completely focused on customer needs and satisfaction. NRG GLOBAL INSTRUMENTS is working hard to increase the reach of technology in every small area across the globe and at the least possible prices. We provide various switches and transmitter for particular usage. Amid all these, Capacitance Level Switch is used for liquid products.

Send Message
product image
Level Switch

NRG GLOBAL vibrating fork is a level switch for liquids and is used in tanks, containers and pipelines.As a sturdy replacement of conventional float switch, Elixir offers a variety of built-in featuresnon-existant in floats and other switches, e.g. where materials are sticky, corrosive, agitated,splashing, foaming and having uncertain electrical properties.Elixir vibrating fork is suitablefor hazardous areas, available with explosion-proof housings certified by CMRI , Dhanbad.Features• Less Power Consumption: Less Heat, Long Life• Universal Power Supply: 18 to 55 V DC,90 to 265 V AC on same terminals• Application Temperature Range : up to 200° C• Suitable up to 10,000 cP (Detects all Industrial Fluids)• Compact Size: Less Inventory• Extendable probe length from 68 to 3000 mm• ECTFE coated, polished & hygienic fork• Output: 8.2V Namur, SPDT & DPDT Relay type currentoutput• Calibration Free, independent of material's dielectricpropertiesPrincipleA specially shaped tuning fork is kept vibrating using piezo-electric elements. Typically, thefork vibrates at its natural frequency. The frequency of oscillation for the tuning fork changeswhen immersed in liquids. The change in frequency is detected by the microprocessorleading to a switching decision.Manufacturing Level Instruments & Speed Monitoring SystemsVersion 2.1Grown...to meet challenges Microcontrollerbased Vibrating Fork Liquid Level Limit SwitchApprovals CE Marking, RoHS Compliance, IP-67 Marking Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Flow Meter

Description : FEDREL / KRANTI Make Woltman Type Water Meter (Cold) Size range : 40 To 500 MM(1½” To 20”) Temp Range : 0°C to 45°C Accuracy Class :Class B (±2 % @ Nominal flow rate) Product Standard : ISO-4064/IS-2373 Body Material cum Standard : IS-210 Gr. FG-200 Dial Details : Magnetic Drive, Extra Dry Dial Protection Class : IP-68 End Details : Flanged Ends to BS: 4504 PN 16 APPLICATIONS · Water Supply Networks · Industries · Agriculture FEATURES AND BENEFITS · Extra Dry Dial · Hermetically sealed register ensures that all internal parts clean and prevents fogging throughout the entire lifetime of the meter. · Robust type body to pass the strongest resistance tests in both static and dynamic conditions. · High quality engineered materials for hydraulics and register pivot ensure high reliability and durability · Shock –resistant material for register and closure. · High performance magnetic transmission ensures no part of the register is in contact with water · Interchangeable spare parts for easy online maintenance · High sensitivity, low pressure loss · In-line strainers are standard. · Available for both cold and hot water. 100% of the products are calibrated and all calibrations results can be provided · Temperature Range = 45°c Description : FEDREL / KRANTI Make Woltman Type Water Meter (Cold) Size range : 40 To 500 MM(1½” To 20”) Temp Range : 0°C to 45°C Accuracy Class :Class B (±2 % @ Nominal flow rate) Product Standard : ISO-4064/IS-2373 Body Material cum Standard : IS-210 Gr. FG-200 Dial Details : Magnetic Drive, Extra Dry Dial Protection Class : IP-68 End Details : Flanged Ends to BS: 4504 PN 16 Additional Information: Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PAKING

Send Message

Still searching for
auxiliary supply?