Vadodara
+919979119649

'25 lph'

Items tagged with '25 lph'

product image
Acrylic Body Rotameter

MAKE : NRG GLOBAL HSN CODE : 90261020 TYPE : ACRYLIC BODY ROTAMETER Name of the Fluid : WATER Temperature : 40 DEG C Pressure : 2-3 KG/CM2 Specific Gravity / Density : 1.0 Viscosity : 1.0 CP M. RANGE : 0 – 10000 LPH MOC (WETTEC PARTS) : P.P End Connection : P.P FLANGE END Process Connection : 2” ASA 150 # RF Float Material : SS304 Float Retainer : P.P Tube Material : ACRYLIC Packing/O-Ring Material : NEOPREN RUBBER GLAND : NA BODY / COVER : SOLID TRANSPARENT ACRYLIC BLOCK Scale : DIRECT ENGRAVED ON BODY Scale Length : 50 – 250 mm Approx. Rangebility : 10:1 Scale Marking : In LPH Accuracy : ±2% F.S.D. Inlet Conn. Orientation : BOTTOM Outlet Conn. Orientation : TOP F/F HIEGHT : 500 MM

Send Message
product image
Flow Rotameter

Metal Variable Area Type Flow Meter are designed to measure flow rate of liquids and gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and float. A magnet encapsulated in float couples with rotating magnets are connected to an indicating pointer. Henceforth, the movement of the float is accurately indicated in terms of flowrate. They are intended for application where high pressure, temperature or corrosive conditions preclude the use of conventional glass tube. These are all Metal Variable Area Type Flow meter design to measure flow rate of Liquids & Gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and a float. A magnet encapsulates in float couples with rotating magnets connected to an indicating pointer, thus the movement of the float, is accurately indicated in terms of flow rate. 2. Working Principle When fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 is created between upper and lower side of the float. The float moves upwards by a force obtained by multiplying the pressure differential by the maximum cross-sectional area of the float. Based on Bemoulli's theorem, the principle mentioned above can be theoretically expressed as follows. Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of which the differential pressure decreases. Upward movement of float stops when the dead load is dynamically balanced by the differential pressure. Tapering of metering tube is so designed that the vertical movement of the float becomes linearly proportional to the rate of flow and the scale is provided to read the position of the float, thus giving birth to flow rate indication. 3. Specifications Accuracy : ± 2% of FSD Rangeability : 10:1 Repeatability : ± 0.5% Temperature Rating : -200 to 250°C Pressure Rating : 40 Bar Flow Direction : Bottom to Top Connections : Flanged, TC End and Screwed Enclosure : IP 65 Weatherproof 4. Design features 1. Simplified piping and reduced space requirements 2. Permanent magnetic link between metering float and motion position transmitter 3. Precision swaged metering tube 4. Guide cartridges easily removable for cleaning 5. Provide with Electrical transmitter, flow indicator or alarm 6. Available F/F Height in 350, 450, 500 mm 7. Available Flange size 15 NB to 150 NB & Flow 200 LPH to 50,000 LPH

Send Message
product image
Metal Tube Rotameter

Metal Tube Rotameter is a Variable Area Flow Meter. It consists of a tapered tube, typically made of steel with a 'float', made of SS or PTFE. The differential pressure across the annulus area is constant. The float moves through the tapered tube up and down with respect to fluid flow. The vertical position of the float as indicated by scale is the measure of the instantaneous flow rate. Specifications : Material of Construction :SS 316 / PTFE Float : SS 316 / PTFE Tube : SS 316 Enclosure: SS Buffed / Die Cast Aluminum Line Size from 15 NB to 100NB Ranges between 25 LPH to 60000LPH Face-To-Face Distance : 250mm Accuracy : +/- 2% of FullScale Measuring Span : 1:10 Scale : Acrylic / Aluminum / SS

Send Message
product image
Industrial Rotameter

Metal Variable Area Type Flow Meter are designed to measure flow rate of liquids and gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and float. A magnet encapsulated in float couples with rotating magnets are connected to an indicating pointer. Henceforth, the movement of the float is accurately indicated in terms of flowrate. They are intended for application where high pressure, temperature or corrosive conditions preclude the use of conventional glass tube. These are all Metal Variable Area Type Flow meter design to measure flow rate of Liquids & Gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and a float. A magnet encapsulates in float couples with rotating magnets connected to an indicating pointer, thus the movement of the float, is accurately indicated in terms of flow rate. 2. Working Principle When fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 is created between upper and lower side of the float. The float moves upwards by a force obtained by multiplying the pressure differential by the maximum cross-sectional area of the float. Based on Bemoulli's theorem, the principle mentioned above can be theoretically expressed as follows. Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of which the differential pressure decreases. Upward movement of float stops when the dead load is dynamically balanced by the differential pressure. Tapering of metering tube is so designed that the vertical movement of the float becomes linearly proportional to the rate of flow and the scale is provided to read the position of the float, thus giving birth to flow rate indication. 3. Specifications Accuracy : ± 2% of FSD Rangeability : 10:1 Repeatability : ± 0.5% Temperature Rating : -200 to 250°C Pressure Rating : 40 Bar Flow Direction : Bottom to Top Connections : Flanged, TC End and Screwed Enclosure : IP 65 Weatherproof 4. Design features 1. Simplified piping and reduced space requirements 2. Permanent magnetic link between metering float and motion position transmitter 3. Precision swaged metering tube 4. Guide cartridges easily removable for cleaning 5. Provide with Electrical transmitter, flow indicator or alarm 6. Available F/F Height in 350, 450, 500 mm 7. Available Flange size 15 NB to 150 NB & Flow 200 LPH to 50,000 LPH

Send Message
product image
Level Switch

1. Product Description NRG GLOBAL Introduced magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters 3. Design features 1. One Moving Component Exists, so that no – wear of float. 2. Suitable for any fluid having Specific Gravity Above 0.7 3. Minimum possible Distance between 2 Level set Points is 75 mm. 4. Accuracy : ± 0.10%, ± 0.25 %, ± 0.5 % on F.S. 5. The switch operates on the principle of magnetic flux coupling with no mechanical connection so that fluid contamination of switch components cannot occur. 4. Ordering Information Information Required to Quote: Material of Construction, Service Medium, Specific Gravity, Max. Pressure & Temperature, Number of Actuating Levels & Their Distance from top of the Connection, Process Connection.

Send Message
product image
Level Switch

1. Product Description NRG GLOBAL Introduced magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters 3. Design features 1. One Moving Component Exists, so that no – wear of float. 2. Suitable for any fluid having Specific Gravity Above 0.7 3. Minimum possible Distance between 2 Level set Points is 75 mm. 4. Accuracy : ± 0.10%, ± 0.25 %, ± 0.5 % on F.S. 5. The switch operates on the principle of magnetic flux coupling with no mechanical connection so that fluid contamination of switch components cannot occur. 4. Ordering Information Information Required to Quote: Material of Construction, Service Medium, Specific Gravity, Max. Pressure & Temperature, Number of Actuating Levels & Their Distance from top of the Connection, Process Connection. Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Switch

Nrg global Instruments make conductivity level sensor PRODUCT DETAILS Medium Temp : -20Deg C to 100 Dec C Special Version : Up to 200 Deg C Electronics : -25oC to +65oC Output : 1 sets of potential free c/o contacts rated at 5 amps, 230VAC for resistive loads per switch point Supply Voltage : 12-30 V Dc Mounting Connection : 1/2" Standard for Rod probe, others as per request and application MODELS : 1)Single Point 2) Multipoint up to 4 points NRG GLOBAL INSTRUMENTS is the leading Capacitance Level Switches manufacturer in India which provides the quality products to its customers. The best thing about our manufacturing is that it is completely focused on customer needs and satisfaction. NRG GLOBAL INSTRUMENTS is working hard to increase the reach of technology in every small area across the globe and at the least possible prices. We provide various switches and transmitter for particular usage. Amid all these, Capacitance Level Switch is used for liquid products.

Send Message
product image
Level Indicator

“NRG GLOBAL INSTRUMENTS’ make Float & Board Level Indicators are designed for an accurate, reliable & trouble free float operated technique used in large non -pressurized storage tanksDirect IndicationThe Float & Board Level Indicators consists of a float connected to a pointer through a rope via a set of pulleys. The pointer glides over a calibrated gauge board, positioned parallel to the tank. The float accurately follows liquid level variations in vertical direction. The horizontal float movement is as such, the pointer in ‘TOP POSITION’ when tank is ‘EMPTY’ and in ‘BOTTOM POSITION’ when ‘FULL’.Gauge ClassificationMeasuring Range : Up to 40 meters. For more than 40 meters please consult factory.Float : P.P/SS304/SS316/SS+PTFE COATED HAVING 10” TO 12”Calibrated Gauge Board : 6” wide x Al white powder coating with black graduations & numericalLeast Count : 10 MMMaximum Temperature : 80°C (PP) / 300°C (SS)Maximum Pressure : 10 KG/CM2Float Wire Rope : Ø2.5mm x SS 316 / SS 304 (multistring) / Ø6mm x PP (multistring)Installation : Grounded Level Tank / Underground Tank (sump) / Overhead TankSpecific Gravity of Fluid : 0.75 TO 2.0Connecting Pipe : Carbon Steel Powder CoatedLocal IndicationDirect : Powder coated Red CI pointer with Nylon Rollers to provide super smooth movement along gauge board. Pointer Tip indicates ‘Level’.Pulley Assemblies : Cadmium Plated Steel Pulley with PTFE bush and SS shaft housed in weather proof CI enclosure.(2 NOS)Protection ConduitHorizontal Limb : MS pipe 25NB x 400mm to 800mm (adjustable)Vertical Limb : MS pipe 25NB x 195mm & 100mm longProcess Connections : 1” 150#Note : Custom made assemblies can be provided for specific applications Additional Information: Item Code: FBLISS09 Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Indicator

NRG GLOBAL INSTRUMENTS MAKE Tubular Level Gauge is used for visual liquid level indication and is the most commonly used instrument in the process industry. It is a simple and reliable device for level reading in atmospheric or pressurized tank applications. It is mounted parallel, along the side of the tank, so as to form a closed loop. As the process level fluctuates, the level in the transparent glass tube changes accordingly and gives local level indication. The Tubular Level Gauge manufactured by NRG GLOBAL INSTRUMENTS incorporates correct design, rugged construction, proper manufacturing techniques and skilled workmanship to give dependable performance and long service life. Material integrity is assured through strict compliance of chemical composition analysis in a standard laboratory.TUBULAR LEVEL GAUGE FEATURES• Choice of Tie Rod or C-Frame Construction.• With or without isolating valve.• Material integrity assured through strict compliance of chemical composition analysis in a Standard Laboratory.• H Grade Borosilicate glass tube 19/25 mm outer dia with Teflon Packing.• Glass tube an be removed online i.e. without disconnection from vessel• Standard Connection: 1/2" / 3/4" / 1" Flange drilled to ASA 150#, others on request• Aluminum/SS scale with 5 mm resolution as standard and 1 mm on request.• Drain Plug 1/2" Vent Plug 3/4" as std and drain/vent valve as optional• Safety Ball check device(optional).• Hydro test pressure: 12 KG/cm2, 100 Deg C max working temperature.• Defrost/illuminator available on request.

Send Message

Still searching for