product image
Tubular Level Gauges

NRG GLOBAL” MAKE FLOAT & BOARD LEVEL INDICATOR MAKE : NRG GLOBAL HSN CODE : 90261020 TYPE : FLOAT & BOARD FLUID : WATER TEMPERATURE : 50O C PRESSURE : 2-3 Kg/Cm2 SPECIFIC GRAVITY / DENSITY : 0.8 -2.0 KG/M3 VISCOSITY (OP / MAX) : 0.7 – 20 Cp MOC OF THE TANK : RCC/ MS / SS CONNECTION FLANGE : MS SLIP ON TYPE FLANGE SIZE : 1” NB ASA 150 # RF SCALE : ALLUMINIUM POWDER COATED HAVING SCREEN PRINTED AND 150 MM WIDTH AND 1 MTR LONG WITH WHITE BACKGROUND AND BLACK MARKING WITH PVC LAMINATED ZERO PLATE : ALUMINIUM POWDER COATED LEAST COUNT : 10 MM INDICATION IN : CM FLOAT : SS 304 HAVING 12” DIA FLOAT WIRE & GUIDE WIRE : SS 304 HAVING 2.5 MM DIA MULTITHRED PULLEY & PIN : SS 304 PULLEY HOUSING : ALLUMINIUM DIE CAST WETAHER PROOF “T” BRACKET FOR SCALE JOINT : MS “T” TYPE AT EVERY METER POWDER COATED TOP BRACKET : MS “L” TYPE POWDER COATED CHECKNUT AND CHECKNUT PIPE: MS CENTER CONNECTING PIPE : MS TELESCOPIC PIPE HAVING ADJUSTABLE UP TO 700 MM LONG AIRROW (INDICATOR) : MS POWDER COATED WITH PP ROLLER WITH RED REDIUM MARKING FASTENER : GI PLATED

Send Message
product image
Level Switch

NRG GLOBAL MAKE side-mounted float level switch is suitable for liquid level control of open or bearing pressure container in industrial process. When the liquid level reaches to high or low limit, relay contact point can be as signal alarm device or the switch in electronic pump circuit. It is used in water treatment, petrochemical, furnace, shipyard etc. It is widely applicable in the condition of high viscosity, high pressure, high temperature because of it is flexible structure, and it can replace the UQK series products. Working principle To use of liquid buoyancy principle. When the floating ball due to buoyancy and moving up and down, the magnetic reed switch in the junction box will be action when it is influence by the arm end magnetic. The same principle is used in the micro switch device. To use of magnets and magnet micro switch arm end of mutual exclusion movement to push the micro switch action. Product purpose SM series float level switch is suitable for liquid level control of open or bearing pressure container in industrial process. When the liquid level reaches to high or low limit, relay contact point can be as signal alarm device or the switch in electronic pump circuit. Specification Application : Liquids Liquid Density : Above 0.5 – 2.0 Liquid Velocity : Upto 500 cp Design Pressure : Upto 40 Kg/cm² Design Temp : Upto 300°C Connection : Flanged to ASA/BS/DIN Screwed BSP/Screwed NPT Material : SS304/SS304L/SS316/SS316L/PP/HDPE/PVC/PVDF Lined/PTFE Lined Other Materials on request Switch Type : Micro, SDPT, DPDT Form : 1 NO+1NC / 2NO+2NC Rating : 5 Amp, 230 VAC OR 24 VDC Enclosure : W-Proof IP65 / Ex-Proof Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Flow Meter

1. Product Description NRG GLOBAL MAKE Turbine flow meter is used for volumetric total flow and/or flow rate measurement and has a relatively simple working principle. As fluid flows through the turbine meter, it impinges upon turbine blades that are free to rotate about an axis along the center line of the turbine housing. The angular (rotational) velocity of the turbine rotor is directly proportional to the fluid velocity flowing through the turbine. The resulting output is taken by an electrical pickoff(s) mounted on the flow meter body. 2. Product Features 1. Highly sensitive to low flow rates 2. Very accurate over its entire flow range 3. Technical Datasheet 3.1 Material of Construction Enclosure : S.S-304/S.S-316 Rotor : S.S-304 Shaft : Hard Stainless Steel-316 with carbon bush Accuracy (standard installation position): +/- 0.5 OR 1% FSD Repeatability: 0.1% Maximum working Pressure : 6 MPa Fluid & Ambient Temperature : -20º C to 120º C Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Flow Meter

NRG GLOBAL OFFER WATERMETERDOMESTIC WATER METER SPECIFICATIONS (15MM, 20MM AND 25MM SIZES) 1.1 GENERAL LAYOUT The complete water meter is to consist of (5) components:  Above ground extruded water meter box and extended lid with slider.  A water meter (Plastic bodied 15mm, 20mm and 25mm) class C volumetric rotary piston liquid sealed register) with unique meter serial number where first two digits indicate year of manufacture.  3 way concentric restrictor valve.  SABS (Blue) lever type consumer ball valve.  Fusion welded PPR pipe assembly tested to 25 bar Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: CORUGATED BOX

Send Message
product image
Flow Meter

· Full Bore Electromagnetic Flow Meter · Best Accuracy :- +/- 0.5 % Of Reading · Excellent Measuring Accuracy To Low Velocity, Measure Double Directions Flows · Buried Sensor (IP 68) No need Measure Well While Instillation; · Precision Coil Winding Technology, Make Magnetic Field More Uniform · Build-in Reference Electrode, No Need Connect Ground Ring; · Dual Frequency Excitation And Stubble Zero Point; · Self-Diagnostic Function, And Intelligent Operation APPLICATION: · ETP/STP Plant · Bore Well Water · Water Base Chemical Mixing Plant · Water Bathing Plant · Ro Plant · Starch Slurry · Food Mixing Plant · Pumping Station Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Flow Meter

NRG GLOBAL INSTRUMENTS MAKE Electromagnetic Flow Meters, simply known as mag flow meter is a volumetric flow meter which is ideally used for waste water applications and other applications that experience low pressure drop and with appropriate liquid conductivity required.The device doesn’t have any moving parts and cannot work with hydrocarbons and distilled water. Mag flow meters are also easy to maintain.Electromagnetic Flow Meters Principle of Magnetic Flow Meter Based on Faraday’s LawMagnetic flow meters works based on Faraday’s Law of Electromagnetic Induction. According to this principle, when a conductive medium passes through a magnetic field B, a voltage E is generated which is proportional to the velocity v of the medium, the density of the magnetic field and the length of the conductor. [E is the voltage generated in a conductor, V is the velocity of the conductor, B is the magnetic field strength and L is the length of the conductor].It is very important that the liquid flow that is to be measured using the magnetic flow meter must be electrically conductive. The Faraday’s Law indicates that the signal voltage (E) is dependent on the average liquid velocity (V), the length of the conductor (D) and the magnetic field strength (B). The magnetic field will thus be established in the cross-section of the tubeBasically when the conductive liquid flows through the magnetic field, voltage is induced. To measure this generated voltage (which is proportional to the velocity of the flowing liquid), two stainless steel electrodes are used which are mounted opposite each other.The two electrodes which are placed inside the flow meter are then connected to an advanced electronic circuit that has the ability to process the signal. The processed signal is fed into the microprocessor that calculates the volumetric flow of the liquid.Electromagnetic Flow Meters Formula:Electromagnetic flow meters use Faraday’s law of electromagnetic induction for making a flow measurement. Faraday’s law states that, whenever a conductor of length ‘l’ moves with a velocity ‘v’ perpendicular to a magnetic field ‘B’, an emf ‘e’ is induced in a mutually perpendicular direction which is given byThus the volume flow rate is proportional to the induced emf. In Practical applications we have to enter the meter constant ‘K’ value in magnetic flow meter which is available in vendor catalog/manual.Applications of Magnetic Flow MetersThis electromagnetic flow meter being non intrusive type, can be used in general for any fluid which is having a reasonable electrical conductivity above 10 microsiemens/cm.Fluids like sand water slurry, coal powder, slurry, sewage, wood pulp, chemicals, water other than distilled water in large pipe lines, hot fluids, high viscous fluids specially in food processing industries, cryogenic fluids can be metered by the electromagnetic flow meter Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Flow Meter

Description : FEDREL / KRANTI Make Woltman Type Water Meter (Cold) Size range : 40 To 500 MM(1½” To 20”) Temp Range : 0°C to 45°C Accuracy Class :Class B (±2 % @ Nominal flow rate) Product Standard : ISO-4064/IS-2373 Body Material cum Standard : IS-210 Gr. FG-200 Dial Details : Magnetic Drive, Extra Dry Dial Protection Class : IP-68 End Details : Flanged Ends to BS: 4504 PN 16 APPLICATIONS · Water Supply Networks · Industries · Agriculture FEATURES AND BENEFITS · Extra Dry Dial · Hermetically sealed register ensures that all internal parts clean and prevents fogging throughout the entire lifetime of the meter. · Robust type body to pass the strongest resistance tests in both static and dynamic conditions. · High quality engineered materials for hydraulics and register pivot ensure high reliability and durability · Shock –resistant material for register and closure. · High performance magnetic transmission ensures no part of the register is in contact with water · Interchangeable spare parts for easy online maintenance · High sensitivity, low pressure loss · In-line strainers are standard. · Available for both cold and hot water. 100% of the products are calibrated and all calibrations results can be provided · Temperature Range = 45°c Description : FEDREL / KRANTI Make Woltman Type Water Meter (Cold) Size range : 40 To 500 MM(1½” To 20”) Temp Range : 0°C to 45°C Accuracy Class :Class B (±2 % @ Nominal flow rate) Product Standard : ISO-4064/IS-2373 Body Material cum Standard : IS-210 Gr. FG-200 Dial Details : Magnetic Drive, Extra Dry Dial Protection Class : IP-68 End Details : Flanged Ends to BS: 4504 PN 16 Additional Information: Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PAKING

Send Message
product image
Magnetic Level Indicator

“NRG GLOBAL” Top Mounted Magnetic Gauge is mounted on top of the tank by a suitable process connection preferably 100 mm NB flange. A float designed for the liquid to be gauged is guided within a stilling well that rest on the process flange. The float is connected to a stem that has a magnet at the upper end moving in a chamber. The float along with the stem and magnet moves up and down with the changing in liquid levels in the vessel. On the dry side of the chamber is the Magnetic Follower Display assembly comprising of a Red & Black PP magnetic capsule housed in a glass tube filled with water. As the float tracks the liquid level the magnet inside the float magnetically couples the Red & Black PP capsule and the capsule will remain magnetically coupled and the level can be read off directly TECHNICAL FEATURES •Simple and robust design. •Pressure and gas proof separation of chamber and display. •Measuring and indication of the level of aggressive, combustible, toxic, hot agitated and contaminated liquids. •Magnetic Follower display without external power. •Available for applications in all areas of industry through use of highly corrosion resistant materials •Designs for a pressure range from full vacuum to 30 bar •Designs for a temperature range from 100C to 250O C •Food industry design. •Interface measurement. OPTIONS: “NRG GLOBAL” Magnetic Switches are used to monitor certain limits of the level. The obtained binary signal can be forwarded to trigger alarms or other controls. • “NRG GLOBAL” Level Sensors are used to transmit the level in conjunction with a “NRG GLOBAL” control unit. This control unit converts the resistance value of the level sensor to a proportional analogue signal Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PAKING