Vadodara
+919979119649

'single chamber'

Items tagged with 'single chamber'

product image

NRG global make simple & easy installation and Direct reading in pressurized tank Wetted Parts in M.S., S.S.304, S.S.316, Polypropylene, Aluminium, M.S.+PTFE, M.S. + P.P Lined, M.S. With Rubber Lined. Isolation Valve & Drain Valve in request Max 3000 mm Length in Single Piece Glass Protected channel available in M.S. S.S.304, S.S.316, FRP Hyd Test Up to 10 Kg/Cm2 Magnetized Float Moves with Level In Extemal Chamber and Magnetic Follower Capsule OR Roller OR Ball Indicates the Liquid Level Externally. Wetted Parts in S.S.304, S.S.316, Polypropylene, PTFE Lined Mainly Use in Furnace Oil, Benzene, Toluene, Ethylene, Alcohol, Acid, Liquid, Gases Like NH3, LPG, SO2, PLC3, etc. High & Low Level Switch, Level Transmitter 4-20 mA, on request. Height up to 5 Mtr Additional Information: Production Capacity: 100 Delivery Time: 1 WEEK Packaging Details: EXPORTWOTHY PACKING

Send Message
product image
Float level Indicator

reading in pressurized tank Wetted Parts in M.S., S.S.304, S.S.316, Polypropylene, Aluminium, M.S.+PTFE, M.S. + P.P Lined, M.S. With Rubber Lined. Isolation Valve & Drain Valve in request Max 3000 mm Length in Single Piece Glass Protected channel available in M.S. S.S.304, S.S.316, FRP Hyd Test Up to 10 Kg/Cm2 Magnetized Float Moves with Level In Extemal Chamber and Magnetic Follower Capsule OR Roller OR Ball Indicates the Liquid Level Externally. Wetted Parts in S.S.304, S.S.316, Polypropylene, PTFE Lined Mainly Use in Furnace Oil, Benzene, Toluene, Ethylene, Alcohol, Acid, Liquid, Gases Like NH3, LPG, SO2, PLC3, etc. High & Low Level Switch, Level Transmitter 4-20 mA, on request. Height up to 5 Mtr Additional Information: Production Capacity: 100 Delivery Time: 1 WEEK Packaging Details: EXPORTWORTY

Send Message
product image
Reflex level indicator

NRG offers a series of Reflex level indicators. Designed to measures the level of liquid in reactor tanks. The reflex level gauge is used for the measurement of liquid level for high pressure or high temperature or toxic liquid storage tanks. The reflex level gauge has a single prism glass mounted on one side of the chamber and uses the basic optical principles of light reflection to upgrade the expression of the liquid level in the process tank. In brief, when the light strikes the area of glass covered by the liquid is allow to pass to the interior of the gauge so that the area appears dark (black). Thus the area which is vacant appears to be (silver) and can be distinguished the difference from several feet away. We are the manufacturer of the reflex level gauge in Gujarat India. Specifications Application: Liquids Liquid Chamber (Wetted Part): MS, ASTM A105, SS 304, SS 316, PP Cover Plate (Non Wetted Part): MS, ASTM A105, SS 304, SS 316, PP Design Temperature: Up to 300°C Design Pressure: Up to 70 Kg/cm² C/C Distance: Up to 3000 mm Connection: Flanged to ASA, BS, DIN, Socket Weld, Butt Weld Applications ► High-pressure vessels ► Pressure Vessle ► Boiler control ► Acid waste transportation ► Marine life science tank ► Spray wash liquid soap ► Remediation vacuum tank ► Chemical distributor tank Available Options ► Reflex level indicator with 2 no’s isolation valve and 1 no Drain valve ► Reflex level indicator without isolation and drain valve ► Reflex level indicator with vertical connection ► Reflex level indicator with spring loaded push valve and drain valve. ► Reflex level indicator with frost free arrangement ► Reflex level indicator with high & low level switch

Send Message
product image
Reflex level indicator

NRG offers a series of Reflex level indicators. Designed to measures the level of liquid in reactor tanks. The reflex level gauge is used for the measurement of liquid level for high pressure or high temperature or toxic liquid storage tanks. The reflex level gauge has a single prism glass mounted on one side of the chamber and uses the basic optical principles of light reflection to upgrade the expression of the liquid level in the process tank. In brief, when the light strikes the area of glass covered by the liquid is allow to pass to the interior of the gauge so that the area appears dark (black). Thus the area which is vacant appears to be (silver) and can be distinguished the difference from several feet away. We are the manufacturer of the reflex level gauge in Gujarat India. Specifications Application: Liquids Liquid Chamber (Wetted Part): MS, ASTM A105, SS 304, SS 316, PP Cover Plate (Non Wetted Part): MS, ASTM A105, SS 304, SS 316, PP Design Temperature: Up to 300°C Design Pressure: Up to 70 Kg/cm² C/C Distance: Up to 3000 mm Connection: Flanged to ASA, BS, DIN, Socket Weld, Butt Weld Applications ► High-pressure vessels ► Pressure Vessle ► Boiler control ► Acid waste transportation ► Marine life science tank ► Spray wash liquid soap ► Remediation vacuum tank ► Chemical distributor tank Available Options ► Reflex level indicator with 2 no’s isolation valve and 1 no Drain valve ► Reflex level indicator without isolation and drain valve ► Reflex level indicator with vertical connection ► Reflex level indicator with spring loaded push valve and drain valve. ► Reflex level indicator with frost free arrangement ► Reflex level indicator with high & low level switch

Send Message
product image
Reflex level indicator

NRG offers a series of Reflex level indicators. Designed to measures the level of liquid in reactor tanks. The reflex level gauge is used for the measurement of liquid level for high pressure or high temperature or toxic liquid storage tanks. The reflex level gauge has a single prism glass mounted on one side of the chamber and uses the basic optical principles of light reflection to upgrade the expression of the liquid level in the process tank. In brief, when the light strikes the area of glass covered by the liquid is allow to pass to the interior of the gauge so that the area appears dark (black). Thus the area which is vacant appears to be (silver) and can be distinguished the difference from several feet away. We are the manufacturer of the reflex level gauge in Gujarat India. Specifications Application: Liquids Liquid Chamber (Wetted Part): MS, ASTM A105, SS 304, SS 316, PP Cover Plate (Non Wetted Part): MS, ASTM A105, SS 304, SS 316, PP Design Temperature: Up to 300°C Design Pressure: Up to 70 Kg/cm² C/C Distance: Up to 3000 mm Connection: Flanged to ASA, BS, DIN, Socket Weld, Butt Weld Applications ► High-pressure vessels ► Pressure Vessle ► Boiler control ► Acid waste transportation ► Marine life science tank ► Spray wash liquid soap ► Remediation vacuum tank ► Chemical distributor tank Available Options ► Reflex level indicator with 2 no’s isolation valve and 1 no Drain valve ► Reflex level indicator without isolation and drain valve ► Reflex level indicator with vertical connection ► Reflex level indicator with spring loaded push valve and drain valve. ► Reflex level indicator with frost free arrangement ► Reflex level indicator with high & low level switch

Send Message
product image
Strainer

NRG GLOBAL MAKE Basket strainers are installed to protect equipment from damage caused by unwanted debris that may be in the pipeline. The unwanted debris could be dirt or other foreign particles that make their way into the process fluid. Typically, basket strainers are installed in horizontal pipelines and in situations where high flow capacity is required. These strainers are installed upstream of equipment like pumps, control valves, and traps, keeping potentially corrosive or damaging debris from making its way down the line. They can be installed alone or in a series to increase filtration. They may come with a single chamber (simplex strainers) or multiple chambers (multiplex strainers). To read more about the differences between simplex and duplex strainers, check out this post. Understanding Mesh Sizing Each strainer is designed with a mesh lined basket to filter and collect the unwanted debris. Mesh size should be chosen based on the job function, not the size of the system. Selecting a mesh with openings that are too small could result in more frequent clogged lines, while a mesh with significantly larger openings could permit more unwanted debris to flow through the pipeline and equipment. Ideally, then, you’ll want to choose a mesh where the perforation is slightly smaller than the smallest particle you’ll need to filter out. Mesh size is measured by the number of openings in one linear inch of screen. For instance, a 16-mesh screen would have 16 openings per inch, while a 100-mesh screen would have 100 openings. Higher numbers, therefore, are able to strain out smaller particles with a finer weave. The baskets are typically made of stainless steel for quality and durability. Factors for Selecting the Right Basket Strainer Each application could require a different basket strainer. Consider the unique functions of your pipeline before deciding on a strainer. Important factors include the pressure and temperature requirements of your line, the type of liquid flow (corrosive, abrasive, etc.), debris size, and the frequency of cleaning and maintenance. You may also consider a duplex style basket strainer (such as these), which holds two strainer baskets fed by diverting valves. This system allows one basket to be cleaned and serviced while the other maintains flow.

Send Message
product image
Magnetic Level Indicator

“NRG GLOBAL” make Magnetic Level Gauge provides clear, high clarity indication of liquid level. Magnetic Level Gauges are principally designed as an alternative to glass level gauges. NRG GLOBAL offers Magnetic Level Gauges in top-bottom, top and side mounted construction with two types of indicator system i.e. Capsule and Bi-colour Rollers. Magnetic Level Gauge is consists of three major components: Float Chamber, Float and Indicator System. Magnetic Level Gauge operates on the principle of magnetic field coupling to provide Fluid Level Information. Float chamber is typically constructed with nonmagnetic pipe having process Connections that matches to the vessel connections. Float size and weight is determined by the process fluid, pressure, temperature and the specific gravity of the process fluid. Float contains magnets to provide 360 ̊magnetic flux field.

Send Message
product image
Level Switch

NRG GLOBAL INSTRUMENTS MAKE magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC OR 230 VAC 1 AMP Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters.. other on your request Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Switch

1. Product Description NRG GLOBAL Introduced magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters 3. Design features 1. One Moving Component Exists, so that no – wear of float. 2. Suitable for any fluid having Specific Gravity Above 0.7 3. Minimum possible Distance between 2 Level set Points is 75 mm. 4. Accuracy : ± 0.10%, ± 0.25 %, ± 0.5 % on F.S. 5. The switch operates on the principle of magnetic flux coupling with no mechanical connection so that fluid contamination of switch components cannot occur. 4. Ordering Information Information Required to Quote: Material of Construction, Service Medium, Specific Gravity, Max. Pressure & Temperature, Number of Actuating Levels & Their Distance from top of the Connection, Process Connection.

Send Message

Still searching for
single chamber?