Vadodara
+919979119649

'pressure signal'

Items tagged with 'pressure signal'

product image
Pressure Transmitter

The diaphragm seal is a pressure-transmitting, diaphragm-type device. The pressure signal is sent to the cooperating pressure measuring device (pressure transmitter, pressure gauge) through manometric liquid filling the space between the separating diaphragm of the seal and the pressure measuring device. The diaphragm seal task is to isolate the pressure measuring device from damaging impacts caused by either medium or installation: – low or high temperature, increased viscosity, impurities; – vibrations of the installation (remote diaphragm seal). Additional Information: Production Capacity: 100 Delivery Time: WITHIN A 10 DAYS Packaging Details: EXPORT

Send Message
product image
Level Switch

NRG GLOBAL MAKE side-mounted float level switch is suitable for liquid level control of open or bearing pressure container in industrial process. When the liquid level reaches to high or low limit, relay contact point can be as signal alarm device or the switch in electronic pump circuit. It is used in water treatment, petrochemical, furnace, shipyard etc. It is widely applicable in the condition of high viscosity, high pressure, high temperature because of it is flexible structure, and it can replace the UQK series products. Working principle To use of liquid buoyancy principle. When the floating ball due to buoyancy and moving up and down, the magnetic reed switch in the junction box will be action when it is influence by the arm end magnetic. The same principle is used in the micro switch device. To use of magnets and magnet micro switch arm end of mutual exclusion movement to push the micro switch action. Product purpose SM series float level switch is suitable for liquid level control of open or bearing pressure container in industrial process. When the liquid level reaches to high or low limit, relay contact point can be as signal alarm device or the switch in electronic pump circuit. Specification Application : Liquids Liquid Density : Above 0.5 – 2.0 Liquid Velocity : Upto 500 cp Design Pressure : Upto 40 Kg/cm² Design Temp : Upto 300°C Connection : Flanged to ASA/BS/DIN Screwed BSP/Screwed NPT Material : SS304/SS304L/SS316/SS316L/PP/HDPE/PVC/PVDF Lined/PTFE Lined Other Materials on request Switch Type : Micro, SDPT, DPDT Form : 1 NO+1NC / 2NO+2NC Rating : 5 Amp, 230 VAC OR 24 VDC Enclosure : W-Proof IP65 / Ex-Proof Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Flow Meter

NRG GLOBAL INSTRUMENTS MAKE Electromagnetic Flow Meters, simply known as mag flow meter is a volumetric flow meter which is ideally used for waste water applications and other applications that experience low pressure drop and with appropriate liquid conductivity required.The device doesn’t have any moving parts and cannot work with hydrocarbons and distilled water. Mag flow meters are also easy to maintain.Electromagnetic Flow Meters Principle of Magnetic Flow Meter Based on Faraday’s LawMagnetic flow meters works based on Faraday’s Law of Electromagnetic Induction. According to this principle, when a conductive medium passes through a magnetic field B, a voltage E is generated which is proportional to the velocity v of the medium, the density of the magnetic field and the length of the conductor. [E is the voltage generated in a conductor, V is the velocity of the conductor, B is the magnetic field strength and L is the length of the conductor].It is very important that the liquid flow that is to be measured using the magnetic flow meter must be electrically conductive. The Faraday’s Law indicates that the signal voltage (E) is dependent on the average liquid velocity (V), the length of the conductor (D) and the magnetic field strength (B). The magnetic field will thus be established in the cross-section of the tubeBasically when the conductive liquid flows through the magnetic field, voltage is induced. To measure this generated voltage (which is proportional to the velocity of the flowing liquid), two stainless steel electrodes are used which are mounted opposite each other.The two electrodes which are placed inside the flow meter are then connected to an advanced electronic circuit that has the ability to process the signal. The processed signal is fed into the microprocessor that calculates the volumetric flow of the liquid.Electromagnetic Flow Meters Formula:Electromagnetic flow meters use Faraday’s law of electromagnetic induction for making a flow measurement. Faraday’s law states that, whenever a conductor of length ‘l’ moves with a velocity ‘v’ perpendicular to a magnetic field ‘B’, an emf ‘e’ is induced in a mutually perpendicular direction which is given byThus the volume flow rate is proportional to the induced emf. In Practical applications we have to enter the meter constant ‘K’ value in magnetic flow meter which is available in vendor catalog/manual.Applications of Magnetic Flow MetersThis electromagnetic flow meter being non intrusive type, can be used in general for any fluid which is having a reasonable electrical conductivity above 10 microsiemens/cm.Fluids like sand water slurry, coal powder, slurry, sewage, wood pulp, chemicals, water other than distilled water in large pipe lines, hot fluids, high viscous fluids specially in food processing industries, cryogenic fluids can be metered by the electromagnetic flow meter Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Magnetic Level Indicator

“NRG GLOBAL” Top Mounted Magnetic Gauge is mounted on top of the tank by a suitable process connection preferably 100 mm NB flange. A float designed for the liquid to be gauged is guided within a stilling well that rest on the process flange. The float is connected to a stem that has a magnet at the upper end moving in a chamber. The float along with the stem and magnet moves up and down with the changing in liquid levels in the vessel. On the dry side of the chamber is the Magnetic Follower Display assembly comprising of a Red & Black PP magnetic capsule housed in a glass tube filled with water. As the float tracks the liquid level the magnet inside the float magnetically couples the Red & Black PP capsule and the capsule will remain magnetically coupled and the level can be read off directly TECHNICAL FEATURES •Simple and robust design. •Pressure and gas proof separation of chamber and display. •Measuring and indication of the level of aggressive, combustible, toxic, hot agitated and contaminated liquids. •Magnetic Follower display without external power. •Available for applications in all areas of industry through use of highly corrosion resistant materials •Designs for a pressure range from full vacuum to 30 bar •Designs for a temperature range from 100C to 250O C •Food industry design. •Interface measurement. OPTIONS: “NRG GLOBAL” Magnetic Switches are used to monitor certain limits of the level. The obtained binary signal can be forwarded to trigger alarms or other controls. • “NRG GLOBAL” Level Sensors are used to transmit the level in conjunction with a “NRG GLOBAL” control unit. This control unit converts the resistance value of the level sensor to a proportional analogue signal Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PAKING

Send Message

Still searching for
pressure signal?