Vadodara
+919979119649

'high sensitivity'

Items tagged with 'high sensitivity'

product image
Flow Meter

Description : FEDREL / KRANTI Make Woltman Type Water Meter (Cold) Size range : 40 To 500 MM(1½” To 20”) Temp Range : 0°C to 45°C Accuracy Class :Class B (±2 % @ Nominal flow rate) Product Standard : ISO-4064/IS-2373 Body Material cum Standard : IS-210 Gr. FG-200 Dial Details : Magnetic Drive, Extra Dry Dial Protection Class : IP-68 End Details : Flanged Ends to BS: 4504 PN 16 APPLICATIONS · Water Supply Networks · Industries · Agriculture FEATURES AND BENEFITS · Extra Dry Dial · Hermetically sealed register ensures that all internal parts clean and prevents fogging throughout the entire lifetime of the meter. · Robust type body to pass the strongest resistance tests in both static and dynamic conditions. · High quality engineered materials for hydraulics and register pivot ensure high reliability and durability · Shock –resistant material for register and closure. · High performance magnetic transmission ensures no part of the register is in contact with water · Interchangeable spare parts for easy online maintenance · High sensitivity, low pressure loss · In-line strainers are standard. · Available for both cold and hot water. 100% of the products are calibrated and all calibrations results can be provided · Temperature Range = 45°c Description : FEDREL / KRANTI Make Woltman Type Water Meter (Cold) Size range : 40 To 500 MM(1½” To 20”) Temp Range : 0°C to 45°C Accuracy Class :Class B (±2 % @ Nominal flow rate) Product Standard : ISO-4064/IS-2373 Body Material cum Standard : IS-210 Gr. FG-200 Dial Details : Magnetic Drive, Extra Dry Dial Protection Class : IP-68 End Details : Flanged Ends to BS: 4504 PN 16 Additional Information: Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PAKING

Send Message
product image
Pressure Gauge

Pressure gauges are instruments designed to measure the pressure of media in a system. Measuring the pressure in your system is a critical quality step to ensure consistency of a product and safety check to be aware of leaks or building pressure in a system. Before specifying a gauge, it is important to understand the basic principles of what pressure is. Then the correct pressure gauge can be determined based on selection criteria, to accurately measure the pressure within the system. Even the best measuring equipment produces a certain deviation from the actual value. It is important to know how this measurement accuracy is defined. Digital gauges in comparison with analog ones have higher accuracy. Read our article on digital pressure gauges if you want to learn more about that type. Additional Information: Item Code: pg Production Capacity: Weeek Delivery Time: week Packaging Details: Export Worthy packing

Send Message
product image
Pressure Transmitter

sanitary pressure transmitters have a flush diaphragm which is suitable for the measurement of viscous fluids or media containing particulates that may clog the pressure connection of standard transmitters. The transmitters have piezoresistive technology which incorporates a silicon sensor. The diaphragm and wetted parts are 316L stainless steel. The stability of the silicon element allows the transmitter to be operated at a higher temperature range; at the same time this makes the zero and sensitivity thermal shifts over the whole operating temperature range of the transmitter very small. • 0...100 bar measuring ranges • 4~20mA current loop output • G1/2 - 1/2" BSP(M) process connection • Flush membrane structure without input pressure hole & cavity • Welded isolated diaphragm • High accuracy, high strength, sanitary type • Dimensions can be customized. • Gauge, absolute and sealed gauge pressure types Additional Information: Production Capacity: 100 Delivery Time: 10 days Packaging Details: export worthy packing

Send Message
product image
Pressure Transmitter

pressure transmitter is a ceramic pressure sensor (If you need higher accuracy and pressure, we have a transmitter with an oil-washed silicon core) that is temperature compensated and laser trimmed for accurate span and offset calibration. The typical advantage is the compact size, which make it convenient to be installed in small room. Some typical applications for these pressure sensor are: Process control and automation, compressors and pumps, engine controls, off road vehicles to name few. Additional Information: Production Capacity: 100 Delivery Time: WITHIN A 10 DAYS Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Tank Level Indicator 3

This is micro-processor based Donnelly Chute level Transmitter with isolated o/p (4-20 mA), 10nos digital optical o/p and 2 relay control .The instrument is field programmable and user friendly. In this Instrument user can set sensor sensitivity, sensor level selection, sample delay time and relay set point etc. The user can set level 2-10 then instrument automatically tunes for o/p 4-20 mA and display 0-100%. The instrument has five settable parameters like rL1,rL2,snt,trl,Lst. The Instrument reads input level in sequence 1 to 10 if misplaced any level then it will not show above levels. Operations Manual – Donnelly Chute Level Transmitter with Modbus Communication Model M11 NX Operations Manual – Donnelly Chute Level Transmitter with Modbus Communication Model M11 MAX Parameters Snt: Sensor Sensitivity adjustment Lst: Level Sensor selection (2-10) Trl: sample Delay adjustment RL1 and rL2 : Relay set point (0-100) snt(sensitivity adjustment Parameter) In this parameter user can set sensitivity of every (1-10 sensor) level sensor through key pad. The sensor value can be set in this parameter 93(Max.) to (185min.) sensitivity and it is normally set 100 value of every sensor. If snt set 93 then i/p led direct on without input connection. Lst(level selection parameter) The user can be set input level 2-10 then instrument automatically tune for o/p 4-20 mA and display 0-100% Trl = 20 set rL1,rL2 : Relay set point value Terminal Details S1 to S10 : i/p for probe type level sensor GND : Common terminal of probe sensor (Donnelly chute sensor) L1 to L10 :o/p for isolated digital out put to plc +24vdc : +v common (+24 vdc) for plc digital i/p O/p 4-20 mA : mA output (isolated) P : common terminal of Relay N/O : Normaly open terminal of Relay N/C : Normaly close terminal of relay L : Phase of 220v AC @50/60Hz N : Neutral E : Earth Specifications Main (auxiliary supply) : 220vAc +-15% @50 Hz O/P (Analog) : isolated 4-20mA O/p (digital : isolated digital output (L1 to L10) Relay set value : 000-100 settable Display range : 0-100% according select sensor level (2-10) settable Time delay setting : 001-100 ms settable Input :10nos. Probe sensor (digital i/p) Digital i/p / o/p : Indicate by LED as fitted on the front panel LED : Red Led for i/p, Green Led optical digital o/p Control Relay : one pair normally open potential free contact: @ 5A at 240v AC Overall size : 96x194x223 mm (WxHxD ) Panel cutout : 184X92mm(HxW) Configuration 1st press both PRG+ DN key for 5 seconds then display rL1 press ENT key display last load value if change then Use up/dn key and press ENT key display rL2 press ENT key display last load value if change then use up/dn key And press ENT key display snt press ENT display 001(it means level 1 select to adjust sensitivity) press ENT display last load value of sensor 1 sensitivity , if you want change value then use up/dn if value decrees (it means sensitivity higher side(93 max.) ) if value increase (it means sensitivity lower side(185 min.) if you want to store modified value then press and hold PRG key after press ENT key now release both key now modified value has been stored . If you do not want to change in this parameter then use only ENT key, if press only ENT key it means by pass snt parameter, if press PRG key and ENT key it means modified value stored and display snt for next level sensor sensitivity calibration And same process apply for level 1 to level 10 after that, Next parameter Lst display press ENT key display last level select if change (2-10) then use up/dn key press ENT key display trL press ENT key display last value and set 20 and press ENT key and now exit configuration mode.

Send Message
product image
Magnetic Level Indicator

“NRG GLOBAL” make Magnetic Level Gauge provides clear, high clarity indication of liquid level. Magnetic Level Gauges are principally designed as an alternative to glass level gauges. NRG GLOBAL offers Magnetic Level Gauges in top-bottom, top and side mounted construction with two types of indicator system i.e. Capsule and Bi-colour Rollers. Magnetic Level Gauge is consists of three major components: Float Chamber, Float and Indicator System. Magnetic Level Gauge operates on the principle of magnetic field coupling to provide Fluid Level Information. Float chamber is typically constructed with nonmagnetic pipe having process Connections that matches to the vessel connections. Float size and weight is determined by the process fluid, pressure, temperature and the specific gravity of the process fluid. Float contains magnets to provide 360 ̊magnetic flux field.

Send Message
product image
Level Switch

Conductivity Level Switch is a simple, low cost, point level measurement switch designed for level detection of conductive liquids having low densities, high viscosities, containing solid particles and to detect interface between non-conductive and conductive liquids. The probes work through the variation of the electrical resistance between the reference electrode and the level-control electrode. Conductivity level switches detect the level resistance when their electrodes are covered by the medium. If the tank is made of plastic, concrete, or any other nonconductive material, an additional electrode is required as a reference Conductivity Level Switches are available with stainless steel 316 electrodes as standard Suitable for many chemicals and aggressive media which are conductive in nature and dirty liquids, liquids with high solid content Construction available with both Solid probes & Suspended probes to suit fitting requirement It is a simple, low cost, point level controller designed for detecton of conductive liquids, having low densites, high viscosities, containing solid particles and interface between nonconductive and conductive liquids. CONSTRUCTION & OPERATION It comprises of a probe, wired to a level controller. The probe holds one common reference/common electrode and one or multiple “Control Electrodes” depending upon the number of levels to be controlled. All the electrodes are suitably insulated to avoid electrical bridging. The lengths of “Control Electrodes” correspond to the height of preset level points to be controlled and the length of the “reference/common Electrode” is kept slightly longer than the longest “Control Electrode”. If tank is conductive, it can be used as a reference/common electrode. Then number of control electrodes equals number of preset levels. Level controller houses sensing electronics consisting of power supply and signal conditoning circuit which provide a “Low AC Voltage” across mass and control electrodes. On liquid reaching preset level point electrical circuit gets completed - generating a signal which is amplified to actuate a relay, those potential free contacts are available for subsequent operations. On “Level Falling” the circuit breaks, deactivating the relay Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PAKING

Send Message

Still searching for
high sensitivity?