Vadodara
+919979119649

'flame front'

Items tagged with 'flame front'

product image
Flame Arrestors

End of Line Flame Arrester : Explanation End of line flame arrester: Flame arrester that is fitted with one pipe connection only. Deflagration = Explosion propagating at subsonic velocity End of line deflagration flame arrester is fitted at the end of vent line. Even at a small pressure difference between storage tank and atmosphere, gas, steam or aerosol escapes through the vent. If this gas, vapor or aerosol is ignited, then flame will propagate through the vent line into storage system. End-of-line deflagration flame arresters stops flame propagation at atmospheric explosion before flame enters into the storage tank.

Send Message
product image
Level Switch

NRG GLOBAL INSTRUMENTS MAKE magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC OR 230 VAC 1 AMP Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters.. other on your request Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Switch

1. Product Description NRG GLOBAL Introduced magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters 3. Design features 1. One Moving Component Exists, so that no – wear of float. 2. Suitable for any fluid having Specific Gravity Above 0.7 3. Minimum possible Distance between 2 Level set Points is 75 mm. 4. Accuracy : ± 0.10%, ± 0.25 %, ± 0.5 % on F.S. 5. The switch operates on the principle of magnetic flux coupling with no mechanical connection so that fluid contamination of switch components cannot occur. 4. Ordering Information Information Required to Quote: Material of Construction, Service Medium, Specific Gravity, Max. Pressure & Temperature, Number of Actuating Levels & Their Distance from top of the Connection, Process Connection.

Send Message
product image
Level Switch

1. Product Description NRG GLOBAL Introduced magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters 3. Design features 1. One Moving Component Exists, so that no – wear of float. 2. Suitable for any fluid having Specific Gravity Above 0.7 3. Minimum possible Distance between 2 Level set Points is 75 mm. 4. Accuracy : ± 0.10%, ± 0.25 %, ± 0.5 % on F.S. 5. The switch operates on the principle of magnetic flux coupling with no mechanical connection so that fluid contamination of switch components cannot occur. 4. Ordering Information Information Required to Quote: Material of Construction, Service Medium, Specific Gravity, Max. Pressure & Temperature, Number of Actuating Levels & Their Distance from top of the Connection, Process Connection. Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Switch

NRG capacitance level TRANSMITTER offers a solution for level limit detection offine, coarse, bulky solids, nonstickyslurries and liquids. The measuring systemconsists of an evaluation unit, an electronic insert and a probe. It works by utilizingthe dielectric property of the application material.PrincipleThe probe comprises of a sense electrode, electrically isolated from the metallic tank bymeans of a suitable insulator. The sense electrode and the vessel wall serve as the twoelectrodes of a capacitor with the service material acting as the dielectric. A change in thelevel of material causes a change in the dielectric, which in turn causes the value of this tankcapacitor to change.Approvals CE Marking, Flameproof Enclosure (Gas Groups IIA, IIB, IIC), RoHS Compliance Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
MAGNETIC Level Switches

1. Product Description NRG GLOBAL Introduced magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters 3. Design features 1. One Moving Component Exists, so that no – wear of float. 2. Suitable for any fluid having Specific Gravity Above 0.7 3. Minimum possible Distance between 2 Level set Points is 75 mm. 4. Accuracy : ± 0.10%, ± 0.25 %, ± 0.5 % on F.S. 5. The switch operates on the principle of magnetic flux coupling with no mechanical connection so that fluid contamination of switch components cannot occur. 4. Ordering Information Information Required to Quote: Material of Construction, Service Medium, Specific Gravity, Max. Pressure & Temperature, Number of Actuating Levels & Their Distance from top of the Connection, Process Connection. Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
MAGNETIC Level Switches

1. Product Description NRG GLOBAL Introduced magnetically float operated Top Mounted Level Switch for controlling one or multi Levels by using reed Switch. The Unit Consists of Vertical Guide Pipe (Stem), Reed Switches Are located, Magnetic Float Sliding over the Stem according to the level in the tank. After passing the float, the reed relay will retain their output state. Various materials of construction are available depending up on Service Condition. Maximum 4 Set points can be given in a Single Level Switch & Maximum stem length will be 3 Meters. 2. Technical Data Float : S.S.316 / SS with PTFE / Poly Propylene Process Connection : Flanged / Screwed / TC Joint Flange : Mini 1” NB to Any Size in C.S. / S.S.304 / S.S.316 / SS with PTFE Coated / P.P. Switch : Hermetically Sealed Magnetically Operated Reed Switch with Rhodium Contact SPST / SPDT. Rating : 0.5 Amps @ 24 V DC Switch Housing : Die Cast Aluminum, Weather Proof IP 65 (Enclosure) / Flame Proof to II A, II B (IS – 2148 CMRS Dhanbad Approved) Operating Pressure : 10 Kg / Cm2 Operating Temp : Max. 90 C. Cable Entry : ½” NPT (F) OR ¾” ET (F) No of Switches : As Per Customer Requirement Stem Length : Up to 3 Meters 3. Design features 1. One Moving Component Exists, so that no – wear of float. 2. Suitable for any fluid having Specific Gravity Above 0.7 3. Minimum possible Distance between 2 Level set Points is 75 mm. 4. Accuracy : ± 0.10%, ± 0.25 %, ± 0.5 % on F.S. 5. The switch operates on the principle of magnetic flux coupling with no mechanical connection so that fluid contamination of switch components cannot occur. 4. Ordering Information Information Required to Quote: Material of Construction, Service Medium, Specific Gravity, Max. Pressure & Temperature, Number of Actuating Levels & Their Distance from top of the Connection, Process Connection.

Send Message

Still searching for
flame front?