Vadodara
+919979119649

'default choice'

Items tagged with 'default choice'

product image
Reflex Transparent Level Gauge

NRG GLOBAL MAKE Reflex Level Gauge use the R-form sight glasses. One side surface of Reflex Glass to use flat glass has several grooves for reflecting prism. The principle of the Reflex Glass is based on the difference in the refractive indices of liquid and gas or in particular of water and steam. Liquid level shows conspicuously dark hard colour for liquid space and light white colour for empty space. These Reflex series are not used with a mica shield. Reflex Level Gauge The Reflex Gauge is assembled firmly with gasket, reflex glass, cushion gasket and gauge cover on the body by Ubolts. Reflex Liquid Level Gauges, designed and built for a wide range of high temperature and high pressure applications. Transparent level gauge may use such as for diesel+water level, process drain+water, etc. In general, a transparent level gauge shall be used as the default choice. This is because a transparent level gauge can do what reflex level gauge does but not vice versa. The transparent level gauge is best used in the interface liquid application and also liquid which are not colorless.

Send Message
product image
Reflex Glass Liquid Level Gauge

NRG GLOBAL MAKE Reflex Level Gauge use the R-form sight glasses. One side surface of Reflex Glass to use flat glass has several grooves for reflecting prism. The principle of the Reflex Glass is based on the difference in the refractive indices of liquid and gas or in particular of water and steam. Liquid level shows conspicuously dark hard colour for liquid space and light white colour for empty space. These Reflex series are not used with a mica shield. Reflex Level Gauge The Reflex Gauge is assembled firmly with gasket, reflex glass, cushion gasket and gauge cover on the body by Ubolts. Reflex Liquid Level Gauges, designed and built for a wide range of high temperature and high pressure applications. Transparent level gauge may use such as for diesel+water level, process drain+water, etc. In general, a transparent level gauge shall be used as the default choice. This is because a transparent level gauge can do what reflex level gauge does but not vice versa. The transparent level gauge is best used in the interface liquid application and also liquid which are not colorless.

Send Message
product image
Reflex Glass Liquid Level Gauge

NRG GLOBAL MAKE Reflex Level Gauge use the R-form sight glasses. One side surface of Reflex Glass to use flat glass has several grooves for reflecting prism. The principle of the Reflex Glass is based on the difference in the refractive indices of liquid and gas or in particular of water and steam. Liquid level shows conspicuously dark hard colour for liquid space and light white colour for empty space. These Reflex series are not used with a mica shield. Reflex Level Gauge The Reflex Gauge is assembled firmly with gasket, reflex glass, cushion gasket and gauge cover on the body by Ubolts. Reflex Liquid Level Gauges, designed and built for a wide range of high temperature and high pressure applications. Transparent level gauge may use such as for diesel+water level, process drain+water, etc. In general, a transparent level gauge shall be used as the default choice. This is because a transparent level gauge can do what reflex level gauge does but not vice versa. The transparent level gauge is best used in the interface liquid application and also liquid which are not colorless.

Send Message
product image
Level Switch

NRG GLOBAL MAKE Displacer type level switches offers the industrial user a wide choice of alarm and control configuration. DLS works on a simple buoyancy principle and is well suited for simple or complex applications, such as forming surging liquids or agitated fluids, and usually costs less than other types of level switches. CONSTRUCTION & OPERATION Operation is based on simple buoyancy principle. As the liquid level rises and progressively immerses the displacer elements, the effective weight suspended on the spring reduces and the consequent length of the spring change is used to provide magnet movement and operate the switch. The spring movement causes the magnetic sleeve to attract a pivoted magnet actuating a switch mechanism located outside the barrier tube. Built-in limit stops, prevent over stroking under level surge conditions. FEATURES: • Wide choice of switching functions • Suitable for large tanks up to 15 meters • Site adjustable switch points • Customized for high temp, high pressure & vaccum applications. • Reliable performance in turbulent liquids even without still pipes. • Easy transportation of longer length switches. • Enclosure : Weather proof-IP-65 Ex-proof-Gr. IIA & IIB or IIC GENERAL SPECIFICATIONS: Enclosure : Cast ALUMINIUM, Weather Proof-IP 65, Cast AL Ex-proof Gr. IIA & IIB or IIC Conduit Connection : ¾ ” ET or ½” NPT Measuring Range : 200 mm~15000 mm Operating Differential : 40±5 mm / Adjustable / 65 ±5 mm Switch Type : Micro switch Switch Contacts : 2 SPDT (2 NO + 2 NC) @ 5A, 230 VAC (Resistive) Switch Action : Bistable Terminals : To suit 1.5 mm2 conductor Flexible Rope : SS304, SS316, PP, PTFE Displacer : SS304, SS316, PP, PTFE Spring Housing : SS316, PP, PTFE Spring Material : SS316, SS316L Process Connection Flanged : MS, SS304, SS316, PP (SS clad), PTFE (SS clad) Perforated still well : MS, SS304, SS316, PP (65 NB) External Cage : MS, SS304, SS316, PP (80 NB) Max. Temperature : 0-200°C (without cooling fins) 0-300°C (with cooling fins) (Contact factory for temperature more than 300°C) Max. Test Pressure : Vaccum to 40 Kg/cm2 (Contact factory for pressure more than 40 Kg/cm2) Min. Sp. Gravity : 0.7 (Contact factory for Sp. Gr. less than 0.7)

Send Message
product image
Level Indicator

NRG GLOBAL INSTRUMENTS MAKE Tubular Level Gauge is used for visual liquid level indication and is the most commonly used instrument in the process industry. It is a simple and reliable device for level reading in atmospheric or pressurized tank applications. It is mounted parallel, along the side of the tank, so as to form a closed loop. As the process level fluctuates, the level in the transparent glass tube changes accordingly and gives local level indication. The Tubular Level Gauge manufactured by NRG GLOBAL INSTRUMENTS incorporates correct design, rugged construction, proper manufacturing techniques and skilled workmanship to give dependable performance and long service life. Material integrity is assured through strict compliance of chemical composition analysis in a standard laboratory.TUBULAR LEVEL GAUGE FEATURES• Choice of Tie Rod or C-Frame Construction.• With or without isolating valve.• Material integrity assured through strict compliance of chemical composition analysis in a Standard Laboratory.• H Grade Borosilicate glass tube 19/25 mm outer dia with Teflon Packing.• Glass tube an be removed online i.e. without disconnection from vessel• Standard Connection: 1/2" / 3/4" / 1" Flange drilled to ASA 150#, others on request• Aluminum/SS scale with 5 mm resolution as standard and 1 mm on request.• Drain Plug 1/2" Vent Plug 3/4" as std and drain/vent valve as optional• Safety Ball check device(optional).• Hydro test pressure: 12 KG/cm2, 100 Deg C max working temperature.• Defrost/illuminator available on request.

Send Message
product image
Displacer Level Switch

NRG GLOBAL MAKE Displacer type level switches offers the industrial user a wide choice of alarm and control configuration. DLS works on a simple buoyancy principle and is well suited for simple or complex applications, such as forming surging liquids or agitated fluids, and usually costs less than other types of level switches. CONSTRUCTION & OPERATION Operation is based on simple buoyancy principle. As the liquid level rises and progressively immerses the displacer elements, the effective weight suspended on the spring reduces and the consequent length of the spring change is used to provide magnet movement and operate the switch. The spring movement causes the magnetic sleeve to attract a pivoted magnet actuating a switch mechanism located outside the barrier tube. Built-in limit stops, prevent over stroking under level surge conditions. FEATURES: • Wide choice of switching functions • Suitable for large tanks up to 15 meters • Site adjustable switch points • Customized for high temp, high pressure & vaccum applications. • Reliable performance in turbulent liquids even without still pipes. • Easy transportation of longer length switches. • Enclosure : Weather proof-IP-65 Ex-proof-Gr. IIA & IIB or IIC

Send Message
product image
Strainer

Basket filters & strainers will permit the straining & filtering of a wide variety of fluids, to retain solids of almost any size. All baskets are easily removable & cleanable. Basket strainer elements can be offered in single cylinder, double cylinder, multi cylinder & pleated design depending upon requirement of application. They are constructed of filter housing, filter element supported with perforated cage, positive sealing arrangement to avoid any bypass & choice of end connections. Operation Unfiltered liquid enters the basket housing and passes down through them. Solids are retained inside/ outside of basket depending upon design and are removed when the unit is serviced.They are available with insitu backwashing arrangement, wherein removal of baskets for cleaning is not required often. Basket filters & strainers are normally supplied with spring arrangement at the top of filter element. This will ensure any type of bypassing & confirm the position of basket, even in case of reverse flow. Fluid bypass around the basket is prevented by an optional O'-Ring seal between the basket rim and the housing inside diameter.

Send Message
product image
Strainer

Basket filters & strainers will permit the straining & filtering of a wide variety of fluids, to retain solids of almost any size. All baskets are easily removable & cleanable. Basket strainer elements can be offered in single cylinder, double cylinder, multi cylinder & pleated design depending upon requirement of application. They are constructed of filter housing, filter element supported with perforated cage, positive sealing arrangement to avoid any bypass & choice of end connections. Operation Unfiltered liquid enters the basket housing and passes down through them. Solids are retained inside/ outside of basket depending upon design and are removed when the unit is serviced.They are available with insitu backwashing arrangement, wherein removal of baskets for cleaning is not required often. Basket filters & strainers are normally supplied with spring arrangement at the top of filter element. This will ensure any type of bypassing & confirm the position of basket, even in case of reverse flow. Fluid bypass around the basket is prevented by an optional O'-Ring seal between the basket rim and the housing inside diameter.

Send Message

Still searching for
default choice?