Vadodara
+919979119649

'rf flow range'

Items tagged with 'rf flow range'

product image
Sight Glass

NRG GLOBAL INSTRUMENTS Manufactures and exporters of Double Window Type Sight Glass (Sight Flow Indicator) in Cast Construction & Fabricated design to meet an industrial requirement of various applications to inspect the process fluid. In Double Window type Sight Flow Indicator (Sight Glass) Contains Two Toughened Glasses Mounted opposite to each other. NRG GLOBAL Double Window Type Sight Glass (Sight Flow Indicator) available with various thickness and diameter of glass to suit various applications respects to fluid pressure and temperature. Double Window Type Sight Glass (Sight Flow Indicator) is very easy to replace glass without dismantling the whole Sight Glass assembly from process line. Double window type Sight Glass gives better performance in application of Higher Pressure & Temperature. Wide range of Toughen Glasses available to suit industrial pressure. All toughen glasses standard as per DIN 7080. Sight Glass body material available ASTM A 216 GR. WCB (Cast Carbon Steel), ASTM A 351 GR. CF 8 (Stainless Steel 304), ASTM A 351 GR. CF 8M (Stainless Steel 316), ASTM A 351 GR. CF 3 (Stainless Steel 304L), ASTM A 351 GR. CF 3M (Stainless Steel 316L), ASTM A 351 GR. CN 7M (Alloy 20) and others on request. Body Hydraulic Test Pressure design up to 17 Kg./Cm2. We also manufacturing Jacketed Type Sight Glass & Steam Jacketed Double Window Type Sight Flow Indicator Investment Casting (I.C.) Body Stainless Steel 304/316/304L/316L/Alloy 20 Sight Glass Flow Indicator Sight Flow Indicator Manufacturing Range - 1"(DN 25) to 12" (DN 300) Additional Information: Item Code: DWSG09 Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Flow Meter

Description : FEDREL / KRANTI Make Woltman Type Water Meter (Cold) Size range : 40 To 500 MM(1½” To 20”) Temp Range : 0°C to 45°C Accuracy Class :Class B (±2 % @ Nominal flow rate) Product Standard : ISO-4064/IS-2373 Body Material cum Standard : IS-210 Gr. FG-200 Dial Details : Magnetic Drive, Extra Dry Dial Protection Class : IP-68 End Details : Flanged Ends to BS: 4504 PN 16 APPLICATIONS · Water Supply Networks · Industries · Agriculture FEATURES AND BENEFITS · Extra Dry Dial · Hermetically sealed register ensures that all internal parts clean and prevents fogging throughout the entire lifetime of the meter. · Robust type body to pass the strongest resistance tests in both static and dynamic conditions. · High quality engineered materials for hydraulics and register pivot ensure high reliability and durability · Shock –resistant material for register and closure. · High performance magnetic transmission ensures no part of the register is in contact with water · Interchangeable spare parts for easy online maintenance · High sensitivity, low pressure loss · In-line strainers are standard. · Available for both cold and hot water. 100% of the products are calibrated and all calibrations results can be provided · Temperature Range = 45°c Description : FEDREL / KRANTI Make Woltman Type Water Meter (Cold) Size range : 40 To 500 MM(1½” To 20”) Temp Range : 0°C to 45°C Accuracy Class :Class B (±2 % @ Nominal flow rate) Product Standard : ISO-4064/IS-2373 Body Material cum Standard : IS-210 Gr. FG-200 Dial Details : Magnetic Drive, Extra Dry Dial Protection Class : IP-68 End Details : Flanged Ends to BS: 4504 PN 16 Additional Information: Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PAKING

Send Message
product image
Sight Flow Indicator

NRG GLOBAL manufactures and exporters of Double Window Type Sight Glass (Sight Flow Indicator) in Cast Construction & Fabricated design to meet an industrial requirement of various applications to inspect the process fluid. In Double Window type Sight Flow Indicator (Sight Glass) Contains Two Toughened Glasses Mounted opposite to each other. NRG GLOBAL Double Window Type Sight Glass (Sight Flow Indicator) available with various thickness and diameter of glass to suit various applications respects to fluid pressure and temperature. Double Window Type Sight Glass (Sight Flow Indicator) is very easy to replace glass without dismantling the whole Sight Glass assembly from process line. Double window type Sight Glass gives better performance in application of Higher Pressure & Temperature. Wide range of Toughen Glasses available to suit industrial pressure. All toughen glasses standard as per DIN 7080. Sight Glass body material available ASTM A 216 GR. WCB (Cast Carbon Steel), ASTM A 351 GR. CF 8 (Stainless Steel 304), ASTM A 351 GR. CF 8M (Stainless Steel 316), ASTM A 351 GR. CF 3 (Stainless Steel 304L), ASTM A 351 GR. CF 3M (Stainless Steel 316L), ASTM A 351 GR. CN 7M (Alloy 20) and others on request. Body Hydraulic Test Pressure design up to 17 Kg./Cm2. We also manufacturing Jacketed Type Sight Glass & Steam Jacketed Double Window Type Sight Flow Indicator Investment Casting (I.C.) Body Stainless Steel 304/316/304L/316L/Alloy 20 Sight Glass Flow Indicator Sight Flow Indicator Manufacturing Range - 1"(DN 25) to 12" (DN 300) Additional Information: Production Capacity: 100 Delivery Time: 15 DAYS Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Sight Flow Indicator

NRG GLOBAL manufactures and exporters of Double Window Type Sight Glass (Sight Flow Indicator) in Cast Construction & Fabricated design to meet an industrial requirement of various applications to inspect the process fluid. In Double Window type Sight Flow Indicator (Sight Glass) Contains Two Toughened Glasses Mounted opposite to each other. NRG GLOBAL Double Window Type Sight Glass (Sight Flow Indicator) available with various thickness and diameter of glass to suit various applications respects to fluid pressure and temperature. Double Window Type Sight Glass (Sight Flow Indicator) is very easy to replace glass without dismantling the whole Sight Glass assembly from process line. Double window type Sight Glass gives better performance in application of Higher Pressure & Temperature. Wide range of Toughen Glasses available to suit industrial pressure. All toughen glasses standard as per DIN 7080. Sight Glass body material available ASTM A 216 GR. WCB (Cast Carbon Steel), ASTM A 351 GR. CF 8 (Stainless Steel 304), ASTM A 351 GR. CF 8M (Stainless Steel 316), ASTM A 351 GR. CF 3 (Stainless Steel 304L), ASTM A 351 GR. CF 3M (Stainless Steel 316L), ASTM A 351 GR. CN 7M (Alloy 20) and others on request. Body Hydraulic Test Pressure design up to 17 Kg./Cm2. We also manufacturing Jacketed Type Sight Glass & Steam Jacketed Double Window Type Sight Flow Indicator Investment Casting (I.C.) Body Stainless Steel 304/316/304L/316L/Alloy 20 Sight Glass Flow Indicator Sight Flow Indicator Manufacturing Range - 1"(DN 25) to 12" (DN 300) Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Flow Measuring Instruments

Oval gear flow meter is one of positive displacement flow meter and ismainly composed of meter shell, oval gear rotor and converter. It is aninstrument used for continuous or discontinuous metering and control ofliquids in the pipeline. It has advantages of large metering range,excellent accuracy, small pressure loss and high viscosity adaptability etc;It has good performance on measuring high-temperature and highviscosityliquids. It is applicable to the calibration and metering of crudeoil, chemical, chemical fiber, traffic, commerce, food, medicine and health,scientific research and military etc.

Send Message
product image
Flow Instruments

MAKE : NRG GLOBAL SERVICES : WATER OPERATING PRESSURE MAX : 10 KG/CM2. OPERATING TEMPERATURE : 40 ̊C MOC : SS 316 ROTTER : SS 410 WORKING CONDUCTIVITY : NOT REQURED PROCESS CONNECTION : SCREWED END MOUNTING : IN LINE HORIZONTAL. MOUNTING TYPE : INBUILT DISPLAY INPUT SUPPLY : 230V AC. DISPLAY : 9 CHARACTER X 2 LINE LED WITH BLUE BACKLIGHT. FLOW RATE : 4 DIGITS LED. TOTAL FLOW : 9 DIGITS LED. ENCLOSURE : ALUMINIUM DIE CAST FLAMEPROOF ACCURACY : +/-1% OF F.S. OUTPUT. STD. : 4 TO 20MA, RS485 SIZE : 40 NB ASA 150 # RF FLOW RANGE : 0 – 20 M3/HR

Send Message
product image
Electromagnetic Flowmeters

NRG GLOBAL” MAKE TURBINE FLOW METER HSN CODE MAKE SERVICES : 90261020 : NRG GLOBAL : FUEL OIL OPERATING PRESSURE MAX : 10 KG/CM2. OPERATING TEMPERATURE : 130 ̊C SPGR : 0.98 – 1.02 MOC ROTTER WORKING CONDUCTIVITY PROCESS CONNECTION MOUNTING MOUNTING TYPE INPUT SUPPLY DISPLAY : SS 316 : SS 410 : NOT REQURED : FLANGE ASA 150# : IN LINE HORIZONTAL. : REMOTE DISPLAY : 230V AC. DT. 11.09.2023 : 9 CHARACTER X 2 LINE LED WITH BLUE BACKLIGHT. BATCH CONTROLLER FLOW RATE TOTAL FLOW ENCLOSURE ACCURACY OUTPUT. STD. FLOW RANGE LINE SIZE QTY PRICE : 4 DIGITS LED. : 9 DIGITS LED. : 96X96 PANAL MOUNTED : +/-2% OF F.S. : 4 TO 20MA, RS485, WITH RELAY OUT PUT : 0 – 50 M3/HR : 3” ASA 150 # RF

Send Message
product image
FLOWMETER

NRG MAKE Electromagnetic Flow Meter MAKE : NRG HSN CODE : 90261020 LIQUID OF MEDIA : SLUDGE LIQUID Operating Pressure Max : 15 KG/cm² Operating Temperature : 40˚C MOC : SS304 Electrode : SS 316 Flow Tube : SS 304 + PTFE LINED Lining : Teflon (PTFE). Working Conductivity : Must be More than 5 Micro s./cm. Process Connection : Flange ASA 150# Mounting : In Line Horizontal. Mounting Type : Integral Input Supply : 230v Ac. Display : 9 Character X 2 Line LED With Blue Backlight. Flow Rate : 4 Digits LED. Total Flow : 9 Digits LED. Enclosure : Flameproof Box (4” Digisafe With 2NOS ¾”ET Entries ) Accuracy : +/-0.5% of F.S. Output. Std. : 4 to 20mA.WITH RS 485 FLOW RANGE : 3 – 30 M3/HR SIZE : 2” NB ASA 150 # RF

Send Message
product image
Flow Meter

1. Product Description NRG GLOBAL MAKE Turbine flow meter is used for volumetric total flow and/or flow rate measurement and has a relatively simple working principle. As fluid flows through the turbine meter, it impinges upon turbine blades that are free to rotate about an axis along the center line of the turbine housing. The angular (rotational) velocity of the turbine rotor is directly proportional to the fluid velocity flowing through the turbine. The resulting output is taken by an electrical pickoff(s) mounted on the flow meter body. 2. Product Features 1. Highly sensitive to low flow rates 2. Very accurate over its entire flow range 3. Technical Datasheet 3.1 Material of Construction Enclosure : S.S-304/S.S-316 Rotor : S.S-304 Shaft : Hard Stainless Steel-316 with carbon bush Accuracy (standard installation position): +/- 0.5 OR 1% FSD Repeatability: 0.1% Maximum working Pressure : 6 MPa Fluid & Ambient Temperature : -20º C to 120º C Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message

Still searching for
rf flow range?