Vadodara
+919979119649

'new calibration'

Items tagged with 'new calibration'

product image
Pressure Transmitter

Diaphragm seal systems are used for demanding measuring requirements with extreme medium temperatures of -90 °C up to +400 °C in the process industry. The diaphragm seal assemblies protect the measuring instrument from aggressive, corrosive, heterogeneous, abrasive, highly viscous or toxic media. With this service, the total costs of the diaphragm seal system can be clearly lowered. In this way, the service life of the measuring instrument can be fully utilised and only the diaphragm seal assembly needs replacement or repair, preventatively or after failure. With preventive maintenance, scheduled in line with planned shutdowns to your plant, you can reduce downtimes. Service can be done both on a mounted process transmitter as well as on a mechanical measuring instrument. Depending on the application case, the service life of the process transmitter is longer than that of the wetted parts. Therefore, only in rare cases must defective diaphragm seal systems be replaced completely, i.e. including the process transmitter. By re-using the process transmitter, WIKA offers a service package with clear cost savings. With the replacement service, through the exchange of the diaphragm seal, the TCO (total cost of ownership) of the measuring location can be reduced considerably. Your benefits Cost saving Fast availability by saving time Functional test of a process transmitter Current material test certificate New calibration of the entire system Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Switch

NRG MAKE vibrating fork is a level switch for liquids and is used in tanks, containers and pipelines.As a sturdy replacement of conventional float switch, Elixir offers a variety of built-in featuresnon-existant in floats and other switches, e.g. where materials are sticky, corrosive, agitated,splashing, foaming and having uncertain electrical properties.Elixir vibrating fork is suitablefor hazardous areas, available with explosion-proof housings certified by CMRI , Dhanbad.Features• Less Power Consumption: Less Heat, Long Life• Universal Power Supply: 18 to 55 V DC,90 to 265 V AC on same terminals• Application Temperature Range : up to 200° C• Suitable up to 10,000 cP (Detects all Industrial Fluids)• Compact Size: Less Inventory• Extendable probe length from 68 to 3000 mm• ECTFE coated, polished & hygienic fork• Output: 8.2V Namur, SPDT & DPDT Relay type currentoutput• Calibration Free, independent of material's dielectricpropertiesPrincipleA specially shaped tuning fork is kept vibrating using piezo-electric elements. Typically, thefork vibrates at its natural frequency. The frequency of oscillation for the tuning fork changeswhen immersed in liquids. The change in frequency is detected by the microprocessorleading to a switching decision.Manufacturing Level Instruments & Speed Monitoring SystemsVersion 2.1Grown...to meet challengesELIXIR Microcontrollerbased Vibrating Fork Liquid Level Limit SwitchApprovals CE Marking, RoHS Compliance, IP-67 Marking Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Switch

NRG GLOBAL vibrating fork is a level switch for liquids and is used in tanks, containers and pipelines.As a sturdy replacement of conventional float switch, Elixir offers a variety of built-in featuresnon-existant in floats and other switches, e.g. where materials are sticky, corrosive, agitated,splashing, foaming and having uncertain electrical properties.Elixir vibrating fork is suitablefor hazardous areas, available with explosion-proof housings certified by CMRI , Dhanbad.Features• Less Power Consumption: Less Heat, Long Life• Universal Power Supply: 18 to 55 V DC,90 to 265 V AC on same terminals• Application Temperature Range : up to 200° C• Suitable up to 10,000 cP (Detects all Industrial Fluids)• Compact Size: Less Inventory• Extendable probe length from 68 to 3000 mm• ECTFE coated, polished & hygienic fork• Output: 8.2V Namur, SPDT & DPDT Relay type currentoutput• Calibration Free, independent of material's dielectricpropertiesPrincipleA specially shaped tuning fork is kept vibrating using piezo-electric elements. Typically, thefork vibrates at its natural frequency. The frequency of oscillation for the tuning fork changeswhen immersed in liquids. The change in frequency is detected by the microprocessorleading to a switching decision.Manufacturing Level Instruments & Speed Monitoring SystemsVersion 2.1Grown...to meet challenges Microcontrollerbased Vibrating Fork Liquid Level Limit SwitchApprovals CE Marking, RoHS Compliance, IP-67 Marking Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Flow Meter

Description : FEDREL / KRANTI Make Woltman Type Water Meter (Cold) Size range : 40 To 500 MM(1½” To 20”) Temp Range : 0°C to 45°C Accuracy Class :Class B (±2 % @ Nominal flow rate) Product Standard : ISO-4064/IS-2373 Body Material cum Standard : IS-210 Gr. FG-200 Dial Details : Magnetic Drive, Extra Dry Dial Protection Class : IP-68 End Details : Flanged Ends to BS: 4504 PN 16 APPLICATIONS · Water Supply Networks · Industries · Agriculture FEATURES AND BENEFITS · Extra Dry Dial · Hermetically sealed register ensures that all internal parts clean and prevents fogging throughout the entire lifetime of the meter. · Robust type body to pass the strongest resistance tests in both static and dynamic conditions. · High quality engineered materials for hydraulics and register pivot ensure high reliability and durability · Shock –resistant material for register and closure. · High performance magnetic transmission ensures no part of the register is in contact with water · Interchangeable spare parts for easy online maintenance · High sensitivity, low pressure loss · In-line strainers are standard. · Available for both cold and hot water. 100% of the products are calibrated and all calibrations results can be provided · Temperature Range = 45°c Description : FEDREL / KRANTI Make Woltman Type Water Meter (Cold) Size range : 40 To 500 MM(1½” To 20”) Temp Range : 0°C to 45°C Accuracy Class :Class B (±2 % @ Nominal flow rate) Product Standard : ISO-4064/IS-2373 Body Material cum Standard : IS-210 Gr. FG-200 Dial Details : Magnetic Drive, Extra Dry Dial Protection Class : IP-68 End Details : Flanged Ends to BS: 4504 PN 16 Additional Information: Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PAKING

Send Message
product image
Level Transmitter

NRG GLOBAL MAKE Magnetic Level Gauges, MLG Series are in widespread use throughout process industries for local level indication of costly, corrosive and viscous liquids including water at saturation temperature in tanks or for interface applications in ambient conditions or under pressure and temperature conditions. Basically designed as an alternative to sight and gauge glass devices, the MLG is now commonly used in both new construction and plant expansion. The float guide pipe prevents sideways movements of float and also sudden movement of float due to turbulence. The level gauges have etched SS scale for level indication. These can be of two types: Flapper Type and Capsul Type. Magnetic level gauges are precision engineered and manufactured to indicate liquid level accurately, reliably, and continuously. These units are completely sealed and require no periodic maintenance. MLGs also eliminate vapor or liquid emission problems common with sight and gauge glasses. Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Pressure Transmitter

pressure transmitter is a ceramic pressure sensor (If you need higher accuracy and pressure, we have a transmitter with an oil-washed silicon core) that is temperature compensated and laser trimmed for accurate span and offset calibration. The typical advantage is the compact size, which make it convenient to be installed in small room. Some typical applications for these pressure sensor are: Process control and automation, compressors and pumps, engine controls, off road vehicles to name few. Additional Information: Production Capacity: 100 Delivery Time: WITHIN A 10 DAYS Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Displacer Level Switch

Displacer controls offer alternative features to the float-operated control. The sensor is a weight (displacer), heavier than the liquid, that is suspended by a spring. When liquid contacts the displacer, a buoyancy force is produced, which causes the effective weight of the displacer to change. This causes the spring to retract slightly to a new equilibrium position. When the spring retracts, the attraction sleeve also moves upward into the field of the external magnet, thus overcoming the force of the bias spring and actuating the switching element.

Send Message
product image
Flow Measuring Instruments

Oval gear flow meter is one of positive displacement flow meter and ismainly composed of meter shell, oval gear rotor and converter. It is aninstrument used for continuous or discontinuous metering and control ofliquids in the pipeline. It has advantages of large metering range,excellent accuracy, small pressure loss and high viscosity adaptability etc;It has good performance on measuring high-temperature and highviscosityliquids. It is applicable to the calibration and metering of crudeoil, chemical, chemical fiber, traffic, commerce, food, medicine and health,scientific research and military etc.

Send Message
product image
Tank Level Indicator 3

This is micro-processor based Donnelly Chute level Transmitter with isolated o/p (4-20 mA), 10nos digital optical o/p and 2 relay control .The instrument is field programmable and user friendly. In this Instrument user can set sensor sensitivity, sensor level selection, sample delay time and relay set point etc. The user can set level 2-10 then instrument automatically tunes for o/p 4-20 mA and display 0-100%. The instrument has five settable parameters like rL1,rL2,snt,trl,Lst. The Instrument reads input level in sequence 1 to 10 if misplaced any level then it will not show above levels. Operations Manual – Donnelly Chute Level Transmitter with Modbus Communication Model M11 NX Operations Manual – Donnelly Chute Level Transmitter with Modbus Communication Model M11 MAX Parameters Snt: Sensor Sensitivity adjustment Lst: Level Sensor selection (2-10) Trl: sample Delay adjustment RL1 and rL2 : Relay set point (0-100) snt(sensitivity adjustment Parameter) In this parameter user can set sensitivity of every (1-10 sensor) level sensor through key pad. The sensor value can be set in this parameter 93(Max.) to (185min.) sensitivity and it is normally set 100 value of every sensor. If snt set 93 then i/p led direct on without input connection. Lst(level selection parameter) The user can be set input level 2-10 then instrument automatically tune for o/p 4-20 mA and display 0-100% Trl = 20 set rL1,rL2 : Relay set point value Terminal Details S1 to S10 : i/p for probe type level sensor GND : Common terminal of probe sensor (Donnelly chute sensor) L1 to L10 :o/p for isolated digital out put to plc +24vdc : +v common (+24 vdc) for plc digital i/p O/p 4-20 mA : mA output (isolated) P : common terminal of Relay N/O : Normaly open terminal of Relay N/C : Normaly close terminal of relay L : Phase of 220v AC @50/60Hz N : Neutral E : Earth Specifications Main (auxiliary supply) : 220vAc +-15% @50 Hz O/P (Analog) : isolated 4-20mA O/p (digital : isolated digital output (L1 to L10) Relay set value : 000-100 settable Display range : 0-100% according select sensor level (2-10) settable Time delay setting : 001-100 ms settable Input :10nos. Probe sensor (digital i/p) Digital i/p / o/p : Indicate by LED as fitted on the front panel LED : Red Led for i/p, Green Led optical digital o/p Control Relay : one pair normally open potential free contact: @ 5A at 240v AC Overall size : 96x194x223 mm (WxHxD ) Panel cutout : 184X92mm(HxW) Configuration 1st press both PRG+ DN key for 5 seconds then display rL1 press ENT key display last load value if change then Use up/dn key and press ENT key display rL2 press ENT key display last load value if change then use up/dn key And press ENT key display snt press ENT display 001(it means level 1 select to adjust sensitivity) press ENT display last load value of sensor 1 sensitivity , if you want change value then use up/dn if value decrees (it means sensitivity higher side(93 max.) ) if value increase (it means sensitivity lower side(185 min.) if you want to store modified value then press and hold PRG key after press ENT key now release both key now modified value has been stored . If you do not want to change in this parameter then use only ENT key, if press only ENT key it means by pass snt parameter, if press PRG key and ENT key it means modified value stored and display snt for next level sensor sensitivity calibration And same process apply for level 1 to level 10 after that, Next parameter Lst display press ENT key display last level select if change (2-10) then use up/dn key press ENT key display trL press ENT key display last value and set 20 and press ENT key and now exit configuration mode.

Send Message

Still searching for
new calibration?