FLOWMETER

NRG MAKE Electromagnetic Flow Meter MAKE : NRG HSN CODE : 90261020 LIQUID OF MEDIA : SLUDGE LIQUID Operating Pressure Max : 15 KG/cm² Operating Temperature : 40˚C MOC : SS304 Electrode : SS 316 Flow Tube : SS 304 + PTFE LINED Lining : Teflon (PTFE). Working Conductivity : Must be More than 5 Micro s./cm. Process Connection : Flange ASA 150# Mounting : In Line Horizontal. Mounting Type : Integral Input Supply : 230v Ac. Display : 9 Character X 2 Line LED With Blue Backlight. Flow Rate : 4 Digits LED. Total Flow : 9 Digits LED. Enclosure : Flameproof Box (4” Digisafe With 2NOS ¾”ET Entries ) Accuracy : +/-0.5% of F.S. Output. Std. : 4 to 20mA.WITH RS 485 FLOW RANGE : 3 – 30 M3/HR SIZE : 2” NB ASA 150 # RF

Send Message
product image
Pressure Transmitter

Process signal indicators are available in for 4-20mA/0-10VDC applications. Designed for easy programming (with only one-page manuals) and fast, no-hassle installation (with color-coded wire sensor terminals), they feature large, 4-digit LED displays that are easily read from a distance. These instruments are designed for use industry standard 4-20mA/0-10VDC signal applications, and offer a 24VDC power supply to power the signal loop. Inputs: Strain gauge, 4-20mA, 0-10VDC 24VDC signal excitation 2 alarm outputs Retransmission of process value: 4-20mA or 0-10VDC Engineering tech support available by email or phone Large inventory of same day shipping items Quick delivery on custom products NRG offer scalable input of pressure, two programmable alarms, and retransmission of process values. Models are available in 90-260VAC or with 24VDC power supply. Sensor excitation is supplied via a 10VDC supply for transducers and a 24VDC supply for amplified output transmitters. NRG 4-20mA loop-powered display provides a local display for 4-20mA transmitters with a 4-pin connection system. Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Flow Instruments

MAKE : NRG GLOBAL SERVICES : WATER OPERATING PRESSURE MAX : 10 KG/CM2. OPERATING TEMPERATURE : 40 ̊C MOC : SS 316 ROTTER : SS 410 WORKING CONDUCTIVITY : NOT REQURED PROCESS CONNECTION : SCREWED END MOUNTING : IN LINE HORIZONTAL. MOUNTING TYPE : INBUILT DISPLAY INPUT SUPPLY : 230V AC. DISPLAY : 9 CHARACTER X 2 LINE LED WITH BLUE BACKLIGHT. FLOW RATE : 4 DIGITS LED. TOTAL FLOW : 9 DIGITS LED. ENCLOSURE : ALUMINIUM DIE CAST FLAMEPROOF ACCURACY : +/-1% OF F.S. OUTPUT. STD. : 4 TO 20MA, RS485 SIZE : 40 NB ASA 150 # RF FLOW RANGE : 0 – 20 M3/HR

Send Message
product image
Electromagnetic Flowmeters

NRG GLOBAL” MAKE TURBINE FLOW METER HSN CODE MAKE SERVICES : 90261020 : NRG GLOBAL : FUEL OIL OPERATING PRESSURE MAX : 10 KG/CM2. OPERATING TEMPERATURE : 130 ̊C SPGR : 0.98 – 1.02 MOC ROTTER WORKING CONDUCTIVITY PROCESS CONNECTION MOUNTING MOUNTING TYPE INPUT SUPPLY DISPLAY : SS 316 : SS 410 : NOT REQURED : FLANGE ASA 150# : IN LINE HORIZONTAL. : REMOTE DISPLAY : 230V AC. DT. 11.09.2023 : 9 CHARACTER X 2 LINE LED WITH BLUE BACKLIGHT. BATCH CONTROLLER FLOW RATE TOTAL FLOW ENCLOSURE ACCURACY OUTPUT. STD. FLOW RANGE LINE SIZE QTY PRICE : 4 DIGITS LED. : 9 DIGITS LED. : 96X96 PANAL MOUNTED : +/-2% OF F.S. : 4 TO 20MA, RS485, WITH RELAY OUT PUT : 0 – 50 M3/HR : 3” ASA 150 # RF

Send Message
product image
Tank Level Indicator 3

This is micro-processor based Donnelly Chute level Transmitter with isolated o/p (4-20 mA), 10nos digital optical o/p and 2 relay control .The instrument is field programmable and user friendly. In this Instrument user can set sensor sensitivity, sensor level selection, sample delay time and relay set point etc. The user can set level 2-10 then instrument automatically tunes for o/p 4-20 mA and display 0-100%. The instrument has five settable parameters like rL1,rL2,snt,trl,Lst. The Instrument reads input level in sequence 1 to 10 if misplaced any level then it will not show above levels. Operations Manual – Donnelly Chute Level Transmitter with Modbus Communication Model M11 NX Operations Manual – Donnelly Chute Level Transmitter with Modbus Communication Model M11 MAX Parameters Snt: Sensor Sensitivity adjustment Lst: Level Sensor selection (2-10) Trl: sample Delay adjustment RL1 and rL2 : Relay set point (0-100) snt(sensitivity adjustment Parameter) In this parameter user can set sensitivity of every (1-10 sensor) level sensor through key pad. The sensor value can be set in this parameter 93(Max.) to (185min.) sensitivity and it is normally set 100 value of every sensor. If snt set 93 then i/p led direct on without input connection. Lst(level selection parameter) The user can be set input level 2-10 then instrument automatically tune for o/p 4-20 mA and display 0-100% Trl = 20 set rL1,rL2 : Relay set point value Terminal Details S1 to S10 : i/p for probe type level sensor GND : Common terminal of probe sensor (Donnelly chute sensor) L1 to L10 :o/p for isolated digital out put to plc +24vdc : +v common (+24 vdc) for plc digital i/p O/p 4-20 mA : mA output (isolated) P : common terminal of Relay N/O : Normaly open terminal of Relay N/C : Normaly close terminal of relay L : Phase of 220v AC @50/60Hz N : Neutral E : Earth Specifications Main (auxiliary supply) : 220vAc +-15% @50 Hz O/P (Analog) : isolated 4-20mA O/p (digital : isolated digital output (L1 to L10) Relay set value : 000-100 settable Display range : 0-100% according select sensor level (2-10) settable Time delay setting : 001-100 ms settable Input :10nos. Probe sensor (digital i/p) Digital i/p / o/p : Indicate by LED as fitted on the front panel LED : Red Led for i/p, Green Led optical digital o/p Control Relay : one pair normally open potential free contact: @ 5A at 240v AC Overall size : 96x194x223 mm (WxHxD ) Panel cutout : 184X92mm(HxW) Configuration 1st press both PRG+ DN key for 5 seconds then display rL1 press ENT key display last load value if change then Use up/dn key and press ENT key display rL2 press ENT key display last load value if change then use up/dn key And press ENT key display snt press ENT display 001(it means level 1 select to adjust sensitivity) press ENT display last load value of sensor 1 sensitivity , if you want change value then use up/dn if value decrees (it means sensitivity higher side(93 max.) ) if value increase (it means sensitivity lower side(185 min.) if you want to store modified value then press and hold PRG key after press ENT key now release both key now modified value has been stored . If you do not want to change in this parameter then use only ENT key, if press only ENT key it means by pass snt parameter, if press PRG key and ENT key it means modified value stored and display snt for next level sensor sensitivity calibration And same process apply for level 1 to level 10 after that, Next parameter Lst display press ENT key display last level select if change (2-10) then use up/dn key press ENT key display trL press ENT key display last value and set 20 and press ENT key and now exit configuration mode.

Send Message
product image
Water Level Indicator

NRG GLOBAL INSTRUMENTS MAKE Tubular Level Gauge is used for visual liquid level indication and is the most commonly used instrument in the process industry. It is a simple and reliable device for level reading in atmospheric or pressurized tank applications. It is mounted parallel, along the side of the tank, so as to form a closed loop. As the process level fluctuates, the level in the transparent glass tube changes accordingly and gives local level indication. The Tubular Level Gauge manufactured by NRG GLOBAL INSTRUMENTS incorporates correct design, rugged construction, proper manufacturing techniques and skilled workmanship to give dependable performance and long service life. Material integrity is assured through strict compliance of chemical composition analysis in a standard laboratory.TUBULAR LEVEL GAUGE FEATURES• Choice of Tie Rod or C-Frame Construction.• With or without isolating valve.• Material integrity assured through strict compliance of chemical composition analysis in a Standard Laboratory.• H Grade Borosilicate glass tube 19/25 mm outer dia with Teflon Packing.• Glass tube an be removed online i.e. without disconnection from vessel• Standard Connection: 1/2" / 3/4" / 1" Flange drilled to ASA 150#, others on request• Aluminum/SS scale with 5 mm resolution as standard and 1 mm on request.• Drain Plug 1/2" Vent Plug 3/4" as std and drain/vent valve as optional• Safety Ball check device(optional).• Hydro test pressure: 12 KG/cm2, 100 Deg C max working temperature.• Defrost/illuminator available on request.• Tie Rod Construction is ‘light' and permits 360ºC visibility.• C-Frame construction is robust and permits observation from Front & Rear.• Both constructions are available in integral or inline arrangements.• High quality, H grade borosilicate glass tube in 19/25mm outer dia is used.• Available in single length having c/c distance = 1600 mm. Extended lengths are provided by coupling several tubes or gauge assemblies in series• Gland packing design provides tension free tube installation to achieve zero leakage. It also enables glass removal for replacement or cleaning without dismantling the gauge or disconnection from the vessel.• Transparent Acrylic Plate mounted on C-Frame/Acrylic Pipe or slotted metallic pipe clamped on Tie Rod as glass protector can be provided if required, for additional safety to glass & personnel.ApplicationsChemical IndustryPetrochemical industryRefineriesPharmaceutical industryPressure vesselsStorage tanksMarine industryWater & Medium StorageProcess TanksHydraulicFiltrationChemical Dosing SystemsWater TreatmentBoiler Drum LevelShips / Bulk Carriers, etc.AdvantagesSimple and rugged constructionEasy mounting Low maintenanceDirect visible level indicationEconomical measurement solutionAssured level indication without power supplySafety auto shut off ball check valve for accidental breakage of glass tubeProtective guard rods or ‘C’ framePermit viewing from any directionAvailable with level indicator for general applicationsEnd connection screwed/flanged as per requirements of the customersConstruction

Send Message
product image
Level Switch

Conductivity Level Switch is a simple, low cost, point level measurement switch designed for level detection of conductive liquids having low densities, high viscosities, containing solid particles and to detect interface between non-conductive and conductive liquids. The probes work through the variation of the electrical resistance between the reference electrode and the level-control electrode. Conductivity level switches detect the level resistance when their electrodes are covered by the medium. If the tank is made of plastic, concrete, or any other nonconductive material, an additional electrode is required as a reference Conductivity Level Switches are available with stainless steel 316 electrodes as standard Suitable for many chemicals and aggressive media which are conductive in nature and dirty liquids, liquids with high solid content Construction available with both Solid probes & Suspended probes to suit fitting requirement It is a simple, low cost, point level controller designed for detecton of conductive liquids, having low densites, high viscosities, containing solid particles and interface between nonconductive and conductive liquids. CONSTRUCTION & OPERATION It comprises of a probe, wired to a level controller. The probe holds one common reference/common electrode and one or multiple “Control Electrodes” depending upon the number of levels to be controlled. All the electrodes are suitably insulated to avoid electrical bridging. The lengths of “Control Electrodes” correspond to the height of preset level points to be controlled and the length of the “reference/common Electrode” is kept slightly longer than the longest “Control Electrode”. If tank is conductive, it can be used as a reference/common electrode. Then number of control electrodes equals number of preset levels. Level controller houses sensing electronics consisting of power supply and signal conditoning circuit which provide a “Low AC Voltage” across mass and control electrodes. On liquid reaching preset level point electrical circuit gets completed - generating a signal which is amplified to actuate a relay, those potential free contacts are available for subsequent operations. On “Level Falling” the circuit breaks, deactivating the relay Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PAKING

Send Message
product image
Level Switch

NRG MAKE vibrating fork is a level switch for liquids and is used in tanks, containers and pipelines.As a sturdy replacement of conventional float switch, Elixir offers a variety of built-in featuresnon-existant in floats and other switches, e.g. where materials are sticky, corrosive, agitated,splashing, foaming and having uncertain electrical properties.Elixir vibrating fork is suitablefor hazardous areas, available with explosion-proof housings certified by CMRI , Dhanbad.Features• Less Power Consumption: Less Heat, Long Life• Universal Power Supply: 18 to 55 V DC,90 to 265 V AC on same terminals• Application Temperature Range : up to 200° C• Suitable up to 10,000 cP (Detects all Industrial Fluids)• Compact Size: Less Inventory• Extendable probe length from 68 to 3000 mm• ECTFE coated, polished & hygienic fork• Output: 8.2V Namur, SPDT & DPDT Relay type currentoutput• Calibration Free, independent of material's dielectricpropertiesPrincipleA specially shaped tuning fork is kept vibrating using piezo-electric elements. Typically, thefork vibrates at its natural frequency. The frequency of oscillation for the tuning fork changeswhen immersed in liquids. The change in frequency is detected by the microprocessorleading to a switching decision.Manufacturing Level Instruments & Speed Monitoring SystemsVersion 2.1Grown...to meet challengesELIXIR Microcontrollerbased Vibrating Fork Liquid Level Limit SwitchApprovals CE Marking, RoHS Compliance, IP-67 Marking Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Switch

Nrg global Instruments make conductivity level sensor PRODUCT DETAILS Medium Temp : -20Deg C to 100 Dec C Special Version : Up to 200 Deg C Electronics : -25oC to +65oC Output : 1 sets of potential free c/o contacts rated at 5 amps, 230VAC for resistive loads per switch point Supply Voltage : 12-30 V Dc Mounting Connection : 1/2" Standard for Rod probe, others as per request and application MODELS : 1)Single Point 2) Multipoint up to 4 points NRG GLOBAL INSTRUMENTS is the leading Capacitance Level Switches manufacturer in India which provides the quality products to its customers. The best thing about our manufacturing is that it is completely focused on customer needs and satisfaction. NRG GLOBAL INSTRUMENTS is working hard to increase the reach of technology in every small area across the globe and at the least possible prices. We provide various switches and transmitter for particular usage. Amid all these, Capacitance Level Switch is used for liquid products.