Vadodara
+919979119649

'high frequency'

Items tagged with 'high frequency'

product image
Pressure Gauge

Pressure gauges are instruments designed to measure the pressure of media in a system. Measuring the pressure in your system is a critical quality step to ensure consistency of a product and safety check to be aware of leaks or building pressure in a system. Before specifying a gauge, it is important to understand the basic principles of what pressure is. Then the correct pressure gauge can be determined based on selection criteria, to accurately measure the pressure within the system. Even the best measuring equipment produces a certain deviation from the actual value. It is important to know how this measurement accuracy is defined. Digital gauges in comparison with analog ones have higher accuracy. Read our article on digital pressure gauges if you want to learn more about that type. Additional Information: Item Code: pg Production Capacity: Weeek Delivery Time: week Packaging Details: Export Worthy packing

Send Message
product image
Level Transmitter

Radar Level Measurementby Editorial Staff Radar level instruments measure the distance from the transmitter (located at some high point) to the surface of a process material located farther below in much the same way as ultrasonic transmitters – by measuring the time-of-flight of a traveling wave. The fundamental difference between a radar instrument and an ultrasonic instrument is the type of wave used: radio waves instead of sound waves. Radio waves are electromagnetic in nature (comprised of alternating electric and magnetic fields), and very high frequency (in the microwave frequency range – GHz). Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: CORRUGATED BOX

Send Message
product image
Level Transmitter

The 80GHz Radar series is NRG radar operating at 76-81 GHz, which has a maximum measuringrange of 120m and nearly zero blind zone. It supports 4-wire and 2-wire applications.Higher operating frequency and shorter wavelength make it ideal for solid applications, includingthose with extreme dust and high temperature to + 2000. Built-in rich algorithm ensure stable outputeven in the application with fast agitator.The main benefitsBased on the self-developed CMOS millimeter wave RF chip, a more compact RF architecture,a higher signal-to-noise ratio, and nearly zero blind zone are realized.5GHz working bandwidth means higher measurement resolution and accuracy.3°antenna beam angle, so the interference in the environment has less impact on the instrument,and the installation is more convenient.Shorter wavelength yields good reflection properties on sloped solids, so aiming towardsmaterial angle of repose is usually not necessary.Remote debugging and remote upgrading is supported to reduce the cost of field personnel

Send Message
product image
Pressure Transmitter

pressure transmitter is a ceramic pressure sensor (If you need higher accuracy and pressure, we have a transmitter with an oil-washed silicon core) that is temperature compensated and laser trimmed for accurate span and offset calibration. The typical advantage is the compact size, which make it convenient to be installed in small room. Some typical applications for these pressure sensor are: Process control and automation, compressors and pumps, engine controls, off road vehicles to name few. Additional Information: Production Capacity: 100 Delivery Time: WITHIN A 10 DAYS Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Strainer

NRG GLOBAL MAKE Basket strainers are installed to protect equipment from damage caused by unwanted debris that may be in the pipeline. The unwanted debris could be dirt or other foreign particles that make their way into the process fluid. Typically, basket strainers are installed in horizontal pipelines and in situations where high flow capacity is required. These strainers are installed upstream of equipment like pumps, control valves, and traps, keeping potentially corrosive or damaging debris from making its way down the line. They can be installed alone or in a series to increase filtration. They may come with a single chamber (simplex strainers) or multiple chambers (multiplex strainers). To read more about the differences between simplex and duplex strainers, check out this post. Understanding Mesh Sizing Each strainer is designed with a mesh lined basket to filter and collect the unwanted debris. Mesh size should be chosen based on the job function, not the size of the system. Selecting a mesh with openings that are too small could result in more frequent clogged lines, while a mesh with significantly larger openings could permit more unwanted debris to flow through the pipeline and equipment. Ideally, then, you’ll want to choose a mesh where the perforation is slightly smaller than the smallest particle you’ll need to filter out. Mesh size is measured by the number of openings in one linear inch of screen. For instance, a 16-mesh screen would have 16 openings per inch, while a 100-mesh screen would have 100 openings. Higher numbers, therefore, are able to strain out smaller particles with a finer weave. The baskets are typically made of stainless steel for quality and durability. Factors for Selecting the Right Basket Strainer Each application could require a different basket strainer. Consider the unique functions of your pipeline before deciding on a strainer. Important factors include the pressure and temperature requirements of your line, the type of liquid flow (corrosive, abrasive, etc.), debris size, and the frequency of cleaning and maintenance. You may also consider a duplex style basket strainer (such as these), which holds two strainer baskets fed by diverting valves. This system allows one basket to be cleaned and serviced while the other maintains flow.

Send Message
product image
Magnetic Level Indicator

“NRG GLOBAL” make Magnetic Level Gauge provides clear, high clarity indication of liquid level. Magnetic Level Gauges are principally designed as an alternative to glass level gauges. NRG GLOBAL offers Magnetic Level Gauges in top-bottom, top and side mounted construction with two types of indicator system i.e. Capsule and Bi-colour Rollers. Magnetic Level Gauge is consists of three major components: Float Chamber, Float and Indicator System. Magnetic Level Gauge operates on the principle of magnetic field coupling to provide Fluid Level Information. Float chamber is typically constructed with nonmagnetic pipe having process Connections that matches to the vessel connections. Float size and weight is determined by the process fluid, pressure, temperature and the specific gravity of the process fluid. Float contains magnets to provide 360 ̊magnetic flux field.

Send Message
product image
Level Switch

Conductivity Level Switch is a simple, low cost, point level measurement switch designed for level detection of conductive liquids having low densities, high viscosities, containing solid particles and to detect interface between non-conductive and conductive liquids. The probes work through the variation of the electrical resistance between the reference electrode and the level-control electrode. Conductivity level switches detect the level resistance when their electrodes are covered by the medium. If the tank is made of plastic, concrete, or any other nonconductive material, an additional electrode is required as a reference Conductivity Level Switches are available with stainless steel 316 electrodes as standard Suitable for many chemicals and aggressive media which are conductive in nature and dirty liquids, liquids with high solid content Construction available with both Solid probes & Suspended probes to suit fitting requirement It is a simple, low cost, point level controller designed for detecton of conductive liquids, having low densites, high viscosities, containing solid particles and interface between nonconductive and conductive liquids. CONSTRUCTION & OPERATION It comprises of a probe, wired to a level controller. The probe holds one common reference/common electrode and one or multiple “Control Electrodes” depending upon the number of levels to be controlled. All the electrodes are suitably insulated to avoid electrical bridging. The lengths of “Control Electrodes” correspond to the height of preset level points to be controlled and the length of the “reference/common Electrode” is kept slightly longer than the longest “Control Electrode”. If tank is conductive, it can be used as a reference/common electrode. Then number of control electrodes equals number of preset levels. Level controller houses sensing electronics consisting of power supply and signal conditoning circuit which provide a “Low AC Voltage” across mass and control electrodes. On liquid reaching preset level point electrical circuit gets completed - generating a signal which is amplified to actuate a relay, those potential free contacts are available for subsequent operations. On “Level Falling” the circuit breaks, deactivating the relay Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PAKING

Send Message

Still searching for
high frequency?