Vadodara
+919979119649

'dead load'

Items tagged with 'dead load'

product image
Acrylic Rotameter

NRG GLOBAL INSTRUMENTS MAKE Glass Tube Variable Area Flow Meters (Rotameters) are intended for general in line and ByPass metering applications (i.e. for Gas & Liquid) where operating conditions are with the limitations of Glass metering tubes. These are the principle of Variable Area. The float moves freely up and down tapered borosilicate glass with fluid flow from bottom to top. The float takes up a position where buoyancy forces and the float weight are balanced in proportion to flow rate. The Vertical position of the float as indicated by scale is the measure of the instantaneous flow rate. 2. Principal of Operation When fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 is created between upper and lower side of the float. The float moves upwards by a force obtained by multiplying the pressure differential by the maximum cross-sectional area of the float. Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of which the differential pressure decreases. Upward movement of float stops when the dead load is dynamically balanced by the differential pressure.

Send Message
product image
Flow Instruments

NRG GLOBAL MAKE Metal Variable Area Type Flow Meter are designed to measure flow rate of liquids and gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and float. A magnet encapsulated in float couples with rotating magnets are connected to an indicating pointer. Henceforth, the movement of the float is accurately indicated in terms of flowrate. They are intended for application where high pressure, temperature or corrosive conditions preclude the use of conventional glass tube. These are all Metal Variable Area Type Flow meter design to measure flow rate of Liquids & Gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and a float. A magnet encapsulates in float couples with rotating magnets connected to an indicating pointer, thus the movement of the float, is accurately indicated in terms of flow rate. 2. Working Principle When fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 is created between upper and lower side of the float. The float moves upwards by a force obtained by multiplying the pressure differential by the maximum cross-sectional area of the float. Based on Bemoulli's theorem, the principle mentioned above can be theoretically expressed as follows. Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of which the differential pressure decreases. Upward movement of float stops when the dead load is dynamically balanced by the differential pressure. Tapering of metering tube is so designed that the vertical movement of the float becomes linearly proportional to the rate of flow and the scale is provided to read the position of the float, thusgiving birth to flow rate indication.

Send Message
product image
Flow Rotameter

Metal Variable Area Type Flow Meter are designed to measure flow rate of liquids and gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and float. A magnet encapsulated in float couples with rotating magnets are connected to an indicating pointer. Henceforth, the movement of the float is accurately indicated in terms of flowrate. They are intended for application where high pressure, temperature or corrosive conditions preclude the use of conventional glass tube. These are all Metal Variable Area Type Flow meter design to measure flow rate of Liquids & Gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and a float. A magnet encapsulates in float couples with rotating magnets connected to an indicating pointer, thus the movement of the float, is accurately indicated in terms of flow rate. 2. Working Principle When fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 is created between upper and lower side of the float. The float moves upwards by a force obtained by multiplying the pressure differential by the maximum cross-sectional area of the float. Based on Bemoulli's theorem, the principle mentioned above can be theoretically expressed as follows. Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of which the differential pressure decreases. Upward movement of float stops when the dead load is dynamically balanced by the differential pressure. Tapering of metering tube is so designed that the vertical movement of the float becomes linearly proportional to the rate of flow and the scale is provided to read the position of the float, thus giving birth to flow rate indication. 3. Specifications Accuracy : ± 2% of FSD Rangeability : 10:1 Repeatability : ± 0.5% Temperature Rating : -200 to 250°C Pressure Rating : 40 Bar Flow Direction : Bottom to Top Connections : Flanged, TC End and Screwed Enclosure : IP 65 Weatherproof 4. Design features 1. Simplified piping and reduced space requirements 2. Permanent magnetic link between metering float and motion position transmitter 3. Precision swaged metering tube 4. Guide cartridges easily removable for cleaning 5. Provide with Electrical transmitter, flow indicator or alarm 6. Available F/F Height in 350, 450, 500 mm 7. Available Flange size 15 NB to 150 NB & Flow 200 LPH to 50,000 LPH

Send Message
product image
Flow Rotameter

1. PRODUCT DESCRIPTIONNRG GLOBAL INSTRUMENTS MAKE Glass Tube Variable Area Flow Meters (Rotameters) are intended for general in line and ByPass metering applications (i.e. for Gas & Liquid) where operating conditions are with the limitations of Glass metering tubes. These are the principle of Variable Area.The float moves freely up and down tapered borosilicate glass with fluid flow from bottom to top. The float takes up a position where buoyancy forces and the float weight are balanced in proportion to flow rate. The Vertical position of the float as indicated by scale is the measure of the instantaneous flow rate.2. PRINCIPAL OF OPERATIONWhen fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 is created between upper and lower side of the float. The float moves upwards by a force obtained by multiplying the pressure differential by the maximum cross-sectional area of the float. Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of which the differential pressure decreases. Upward movement of float stops when the deadload is dynamically balanced by the differential pressure.

Send Message
product image
Metal Tube Rotameter

Metal Variable Area Type Flow Meter are designed to measure flow rate of liquids and gases undercritical conditions. It consists of a tapered metal tube, an indicating assembly and float. A magnetencapsulated in float couples with rotating magnets are connected to an indicating pointer. Henceforth,the movement of the float is accurately indicated in terms of flowrate.They are intended for application where high pressure, temperature or corrosive conditions precludethe use of conventional glass tube. These are all Metal Variable Area Type Flow meter design to measureflow rate of Liquids & Gases under critical conditions. It consists of a tapered metal tube, an indicatingassembly and a float. A magnet encapsulates in float couples with rotating magnets connected to anindicating pointer, thus the movement of the float, is accurately indicated in terms of flow rate.2. Working PrincipleWhen fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 iscreated between upper and lower side of the float. The float moves upwards by a force obtained bymultiplying the pressure differential by the maximum cross-sectional area of the float.Based on Bemoulli's theorem, the principle mentioned above can be theoretically expressed asfollows. Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of which thedifferential pressure decreases. Upward movement of float stops when the dead load is dynamically balanced by the differential pressure. Tapering of metering tube is so designed that the vertical movement of the float becomes linearly proportional to the rate of flow and the scale is provided to read the position of the float, thusgiving birth to flow rate indication.

Send Message
product image
Industrial Rotameter

Metal Variable Area Type Flow Meter are designed to measure flow rate of liquids and gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and float. A magnet encapsulated in float couples with rotating magnets are connected to an indicating pointer. Henceforth, the movement of the float is accurately indicated in terms of flowrate. They are intended for application where high pressure, temperature or corrosive conditions preclude the use of conventional glass tube. These are all Metal Variable Area Type Flow meter design to measure flow rate of Liquids & Gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and a float. A magnet encapsulates in float couples with rotating magnets connected to an indicating pointer, thus the movement of the float, is accurately indicated in terms of flow rate. 2. Working Principle When fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 is created between upper and lower side of the float. The float moves upwards by a force obtained by multiplying the pressure differential by the maximum cross-sectional area of the float. Based on Bemoulli's theorem, the principle mentioned above can be theoretically expressed as follows. Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of which the differential pressure decreases. Upward movement of float stops when the dead load is dynamically balanced by the differential pressure. Tapering of metering tube is so designed that the vertical movement of the float becomes linearly proportional to the rate of flow and the scale is provided to read the position of the float, thus giving birth to flow rate indication. 3. Specifications Accuracy : ± 2% of FSD Rangeability : 10:1 Repeatability : ± 0.5% Temperature Rating : -200 to 250°C Pressure Rating : 40 Bar Flow Direction : Bottom to Top Connections : Flanged, TC End and Screwed Enclosure : IP 65 Weatherproof 4. Design features 1. Simplified piping and reduced space requirements 2. Permanent magnetic link between metering float and motion position transmitter 3. Precision swaged metering tube 4. Guide cartridges easily removable for cleaning 5. Provide with Electrical transmitter, flow indicator or alarm 6. Available F/F Height in 350, 450, 500 mm 7. Available Flange size 15 NB to 150 NB & Flow 200 LPH to 50,000 LPH

Send Message
product image
Level Switch

Nrg global Instruments make conductivity level sensor PRODUCT DETAILS Medium Temp : -20Deg C to 100 Dec C Special Version : Up to 200 Deg C Electronics : -25oC to +65oC Output : 1 sets of potential free c/o contacts rated at 5 amps, 230VAC for resistive loads per switch point Supply Voltage : 12-30 V Dc Mounting Connection : 1/2" Standard for Rod probe, others as per request and application MODELS : 1)Single Point 2) Multipoint up to 4 points NRG GLOBAL INSTRUMENTS is the leading Capacitance Level Switches manufacturer in India which provides the quality products to its customers. The best thing about our manufacturing is that it is completely focused on customer needs and satisfaction. NRG GLOBAL INSTRUMENTS is working hard to increase the reach of technology in every small area across the globe and at the least possible prices. We provide various switches and transmitter for particular usage. Amid all these, Capacitance Level Switch is used for liquid products.

Send Message
product image
Level Switch

PRINCIPALA SMALL ELECTRIC MOTOR DRIVES THE PADDLE, WHICH ROTATES FREELY IN THE ABSENCE OF MATERIAL. IMPEDED BY MATERIAL THE MOTOR WILL BE TURNED WITHIN THE HOUSING WHILE LOADING A SPRING AND TRIGGERING TWO SWITCHES. ONE OF THEM IS A DRY ELECTRIC CONTACT FOR CONTROL AND ALARM FUNCTIONS WHILE THE OTHER CUTS THE POWER TO THE MOTOR. WHEN THE MATERIAL LEVEL DROPS, THE LOADED STRETCHED TENSION SPRING RETURNS THE MOTOR TO ITS ORIGINAL POSITION AND THE UNIT IS REACTIVATEDFEATURES• SPECIAL CLUTCH DESIGN(NON MAGNETIC)• FLEXIBLE COUPLING (OPTIONAL AS PER APPLICATION)• ROBUST, DUST AND WATERTIGHT HOUSING• EXTENDED PROBE POSSIBLE.• SEALED BEARINGS• INTERCHANGEABLE PADDLE ASSEMBLIES• 1 SPDT ( MICROSWITCH )APPLICATIONS• DRY SAND & FLY ASH• PET / PVC CHIPS WITH UNDER WATER DETECTION• RICE, WHEAT, OTHER FOOD GRAIN, FLOUR• IRON ORE, SINTERS AND PULVERIZED COAL• MILK POWDER Additional Information: Production Capacity: 100 Delivery Time: ex stock Packaging Details: export worthy packing

Send Message
product image
Level Switch

PRINCIPALA SMALL ELECTRIC MOTOR DRIVES THE PADDLE, WHICH ROTATES FREELY IN THE ABSENCE OF MATERIAL. IMPEDED BY MATERIAL THE MOTOR WILL BE TURNED WITHIN THE HOUSING WHILE LOADING A SPRING AND TRIGGERING TWO SWITCHES. ONE OF THEM IS A DRY ELECTRIC CONTACT FOR CONTROL AND ALARM FUNCTIONS WHILE THE OTHER CUTS THE POWER TO THE MOTOR. WHEN THE MATERIAL LEVEL DROPS, THE LOADED STRETCHED TENSION SPRING RETURNS THE MOTOR TO ITS ORIGINAL POSITION AND THE UNIT IS REACTIVATEDFEATURES• SPECIAL CLUTCH DESIGN(NON MAGNETIC)• FLEXIBLE COUPLING (OPTIONAL AS PER APPLICATION)• ROBUST, DUST AND WATERTIGHT HOUSING• EXTENDED PROBE POSSIBLE.• SEALED BEARINGS• INTERCHANGEABLE PADDLE ASSEMBLIES• 1 SPDT ( MICROSWITCH )APPLICATIONS• DRY SAND & FLY ASH• PET / PVC CHIPS WITH UNDER WATER DETECTION• RICE, WHEAT, OTHER FOOD GRAIN, FLOUR• IRON ORE, SINTERS AND PULVERIZED COAL• MILK POWDER Additional Information: Production Capacity: 100 Delivery Time: ex stock Packaging Details: export worthy packing

Send Message

Still searching for
dead load?