Vadodara
+919979119649

'level measurement'

Items tagged with 'level measurement'

product image
Level Switch

Conductivity Level Switch is a simple, low cost, point level measurement switch designed for level detection of conductive liquids having low densities, high viscosities, containing solid particles and to detect interface between non-conductive and conductive liquids. The probes work through the variation of the electrical resistance between the reference electrode and the level-control electrode. Conductivity level switches detect the level resistance when their electrodes are covered by the medium. If the tank is made of plastic, concrete, or any other nonconductive material, an additional electrode is required as a reference Conductivity Level Switches are available with stainless steel 316 electrodes as standard Suitable for many chemicals and aggressive media which are conductive in nature and dirty liquids, liquids with high solid content Construction available with both Solid probes & Suspended probes to suit fitting requirement It is a simple, low cost, point level controller designed for detecton of conductive liquids, having low densites, high viscosities, containing solid particles and interface between nonconductive and conductive liquids. CONSTRUCTION & OPERATION It comprises of a probe, wired to a level controller. The probe holds one common reference/common electrode and one or multiple “Control Electrodes” depending upon the number of levels to be controlled. All the electrodes are suitably insulated to avoid electrical bridging. The lengths of “Control Electrodes” correspond to the height of preset level points to be controlled and the length of the “reference/common Electrode” is kept slightly longer than the longest “Control Electrode”. If tank is conductive, it can be used as a reference/common electrode. Then number of control electrodes equals number of preset levels. Level controller houses sensing electronics consisting of power supply and signal conditoning circuit which provide a “Low AC Voltage” across mass and control electrodes. On liquid reaching preset level point electrical circuit gets completed - generating a signal which is amplified to actuate a relay, those potential free contacts are available for subsequent operations. On “Level Falling” the circuit breaks, deactivating the relay Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PAKING

Send Message
product image
Magnetic Level Indicator

“NRG GLOBAL” Top Mounted Magnetic Gauge is mounted on top of the tank by a suitable process connection preferably 100 mm NB flange. A float designed for the liquid to be gauged is guided within a stilling well that rest on the process flange. The float is connected to a stem that has a magnet at the upper end moving in a chamber. The float along with the stem and magnet moves up and down with the changing in liquid levels in the vessel. On the dry side of the chamber is the Magnetic Follower Display assembly comprising of a Red & Black PP magnetic capsule housed in a glass tube filled with water. As the float tracks the liquid level the magnet inside the float magnetically couples the Red & Black PP capsule and the capsule will remain magnetically coupled and the level can be read off directly TECHNICAL FEATURES •Simple and robust design. •Pressure and gas proof separation of chamber and display. •Measuring and indication of the level of aggressive, combustible, toxic, hot agitated and contaminated liquids. •Magnetic Follower display without external power. •Available for applications in all areas of industry through use of highly corrosion resistant materials •Designs for a pressure range from full vacuum to 30 bar •Designs for a temperature range from 100C to 250O C •Food industry design. •Interface measurement. OPTIONS: “NRG GLOBAL” Magnetic Switches are used to monitor certain limits of the level. The obtained binary signal can be forwarded to trigger alarms or other controls. • “NRG GLOBAL” Level Sensors are used to transmit the level in conjunction with a “NRG GLOBAL” control unit. This control unit converts the resistance value of the level sensor to a proportional analogue signal Additional Information: Production Capacity: 100 Delivery Time: WEEK Packaging Details: EXPORT WORTHY PAKING

Send Message
product image
Magnetic Level Indicator

“NRG GLOBAL INSTRUMENTS” Top Mounted Magnetic Gauge is mounted on top of the tank by a suitable process connection preferably 100 mm NB flange. A float designed for the liquid to be gauged is guided within a stilling well that rest on the process flange. The float is connected to a stem that has a magnet at the upper end moving in a chamber. The float along with the stem and magnet moves up and down with the changing in liquid levels in the vessel. On the dry side of the chamber is the Magnetic Follower Display assembly comprising of a Red & Black PP magnetic capsule housed in a glass tube filled with water. As the float tracks the liquid level the magnet inside the float magnetically couples the Red & Black PP capsule and the capsule will remain magnetically coupled and the level can be read off directly TECHNICAL FEATURES •Simple and robust design. •Pressure and gas proof separation of chamber and display. •Measuring and indication of the level of aggressive, combustible, toxic, hot agitated and contaminated liquids. •Magnetic Follower display without external power. •Available for applications in all areas of industry through use of highly corrosion resistant materials •Designs for a pressure range from full vacuum to 30 bar •Designs for a temperature range from 100C to 250O C •Food industry design. •Interface measurement. Additional Information: Item Code: TMMLI Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Transmitter

Radar Level Measurementby Editorial Staff Radar level instruments measure the distance from the transmitter (located at some high point) to the surface of a process material located farther below in much the same way as ultrasonic transmitters – by measuring the time-of-flight of a traveling wave. The fundamental difference between a radar instrument and an ultrasonic instrument is the type of wave used: radio waves instead of sound waves. Radio waves are electromagnetic in nature (comprised of alternating electric and magnetic fields), and very high frequency (in the microwave frequency range – GHz). Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: CORRUGATED BOX

Send Message
product image
Level Transmitter

NRG MAKE Float level transmitter provides continuous level measurement up to 2 m (6.5') with a 4 to 20 mA signal output, and is factory configured to your selected dimension. This stainless steel liquid level sensor is well suited for high temperature or pressure tank level applications with relatively clean liquids such as water, diluted chemicals and light weight oils. Typical application examples include boilers and process vessels. Specifications Range: 41 to 1222 cm (16 to 48") Accuracy: 0.25% span in water Configuration: None, fixed span Orientation: ±20° from vertical Specific Gravity: 0.55 min Supply Voltage: 10 to 30 Vdc Loop Resistance: 600 Ω @ 24 Vdc Signal Output: 4 to 20 mA, two-wire Process Temp: -40 to 85°C (-40 to 185°F) Ambient Temp: -40 to 60°C (-40 to 140°F) Pressure: 200 psi (13.8 bar) Enclosure Rating: NEMA 4X (IP65) Enclosure Material: PP Conduit Entrance: Single, 1/2 NPT Process Mount: 2 NPT Guide-Float Material: 316 SS Classification: General purpose Additional Information: Item Code: flt Production Capacity: 50 Delivery Time: week Packaging Details: Export worthy packing

Send Message
product image
Level Transmitter

NRG GLOBAL INSTRUMENTS MAKE microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-15 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action ACTION PARAMETER - if we mention the value of action parameter as 1 then it will work in reverse order and if value is mentioned as 0 it will work in forward order. RANGE PARAMETER – in range parameter we have to define that value which gives the output of 420mA. WORKING OF TRANSMITTER- (REVERSE ACTION ) if we mention the value of action parameter as 1 , suppose the object is placed 1 m (value of range parameter ) from the transmitter then this value will be considered zero and as the object will move closer to it ,it will begin to sense the distance and will give the output as soon as when the object will be at 22cm it will display maximum range i.e 420 mA. Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Transmitter

NRG GLOBAL MAKE microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-15 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action ACTION PARAMETER - if we mention the value of action parameter as 1 then it will work in reverse order and if value is mentioned as 0 it will work in forward order. RANGE PARAMETER – in range parameter we have to define that value which gives the output of 420mA. WORKING OF TRANSMITTER- (REVERSE ACTION ) if we mention the value of action parameter as 1 , suppose the object is placed 1 m (value of range parameter ) from the transmitter then this value will be considered zero and as the object will move closer to it ,it will begin to sense the distance and will give the output as soon as when the object will be at 22cm it will display maximum range i.e 420 mA. Additional Information: Production Capacity: 100 Delivery Time: EX STOCK Packaging Details: EXPORT WORTHY PACKING

Send Message
product image
Level Transmitter

This is microprocessor based Ultrasonic level transmitter. It has Multifunction Instruments It is capable of monitoring Virtually Any Short Or Medium Range of Non-Contact Ultrasonic Level Measurements of Liquids, Solids Or Slurries. In this Instrument User can take measurements of Roller Lift of mills, water level and select the range in the range parameter and set Reverse action in Action parameter. It has One Analog Output 4-20mA and two digital control output (we can also define these two digital control output as relay1and 2). NOTE – To measure the level t of the tank ,the sensor has to be placed 22cm above the level as it is defined as the dead zone of the sensor . SPESCIFICATION Measuring Range : 0-10 Meters Main (auxiliary supply) : 24V DC O/P (Analog) : 4-20mA Digital (RL1&2) : +24v common Display LCD : 16 x2 Display value : In CM And MM(Millimeter) Revers Action : User can be take 4-20mA in revers action

Send Message
product image
Reflex level indicator

NRG offers a series of Reflex level indicators. Designed to measures the level of liquid in reactor tanks. The reflex level gauge is used for the measurement of liquid level for high pressure or high temperature or toxic liquid storage tanks. The reflex level gauge has a single prism glass mounted on one side of the chamber and uses the basic optical principles of light reflection to upgrade the expression of the liquid level in the process tank. In brief, when the light strikes the area of glass covered by the liquid is allow to pass to the interior of the gauge so that the area appears dark (black). Thus the area which is vacant appears to be (silver) and can be distinguished the difference from several feet away. We are the manufacturer of the reflex level gauge in Gujarat India. Specifications Application: Liquids Liquid Chamber (Wetted Part): MS, ASTM A105, SS 304, SS 316, PP Cover Plate (Non Wetted Part): MS, ASTM A105, SS 304, SS 316, PP Design Temperature: Up to 300°C Design Pressure: Up to 70 Kg/cm² C/C Distance: Up to 3000 mm Connection: Flanged to ASA, BS, DIN, Socket Weld, Butt Weld Applications ► High-pressure vessels ► Pressure Vessle ► Boiler control ► Acid waste transportation ► Marine life science tank ► Spray wash liquid soap ► Remediation vacuum tank ► Chemical distributor tank Available Options ► Reflex level indicator with 2 no’s isolation valve and 1 no Drain valve ► Reflex level indicator without isolation and drain valve ► Reflex level indicator with vertical connection ► Reflex level indicator with spring loaded push valve and drain valve. ► Reflex level indicator with frost free arrangement ► Reflex level indicator with high & low level switch

Send Message

Still searching for
level measurement?